3
LIGHTING INSTRUCTIONS
!
WARNING
Before lighting any type of pilot burner
(standing or intermittent), make certain hot
water boiler and system are full of water to
minimum pressure of 12 lbs. per square inch
in the system, and also make certain the
system is vented of air. Refer to following
appropriate lighting instruction.
LIGHTING PROCEDURE FOR BOILER WITH
INTERMITTENT PILOT SYSTEM
!
WARNING
If you do not follow these instructions exactly,
a fire or explosion may result causing property
damage, personal injury or loss of life.
This appliance is equipped with an ignition device
A.
which automatically lights the pilot. Do not try to
light the appliance by hand.
Before operating, smell all around the appliance area
B.
for gas. Be sure to smell next to the floor because
some gas is heavier than air and will settle on the
floor. Read
"What To Do If You Smell Gas" on front
page of this manual.
Use only your hand to push in or turn the gas control
C.
knob. Never use tools. If the knob will not push in
or turn by hand, don’t try to repair it, call a qualified
service technician. Force or attempted repair may
result in a fire or explosion.
Do not use this appliance if any part has been under
D.
water. Immediately call a qualified service technician
to inspect the appliance and to replace any part of
the control system and any gas control which has
been under water.
E.
F.
Operating Instructions For
Intermittent Pilot
System
STOP!
1.
Read the safety information above.
Set the thermostat to lowest setting.
2.
Turn off all electric power to the appliance.
3.
This appliance is equipped with an ignition device which
4.
automatically lights the pilot. Do not try to light pilot by
hand.
Remove jacket front panel.
5.
Turn gas control knob clockwise
6.
to “OFF.” See
Figure 1.
Wait (5) minutes to clear out any gas. If you then smell
7.
gas,
STOP! Follow “What To Do If You Smell Gas” on
front cover of this manual. If you don’t smell gas, go on
to the next step.
Turn gas control knob counterclockwise
8.
to “ON.”
Replace jacket front panel.
9.
Turn on all electric power to the appliance.
10.
Set thermostat to desired setting.
11.
If the appliance will not operate, follow the instructions
12.
“To Turn Off Gas To Appliance”
on page 4 and call a
qualified service technician or your gas supplier.
Figure 1 - Intermittent Pilot