background image

连接接口

Specification

连接接口

Item 

Description 

Power

Power Supply

Power adapter supply

Voltage Range 

DC 12V 

Consumption

<2W

Ethernet Port 

Parameter

Ethernet Port

 EOC: 0--100Mbps Ethernet port:10/100Mbps;

transmission bandwidth changes based on 

transmission distance, please refer to table 1

Transmission Distance

EOC coaxial cable: 0-1200m

EOC network cable: 0-700m

Transmission Medium

75-5 or above coaxial cable and Cat5e/6 cable

Ethernet

Exchange

Ethernet standard

IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX

Ethernet delay

<1ms

Status

LED Indicator 

Input/output ports:

power status(RJ45 yellow)

network signal transmission(RJ45 green);

EOC: indicate cable connection(RJ45 yellow/green)

Protection 

Level

ESD

1a Contact Discharge level 3

1b Air Discharge  level 3

IEC61000-4-2

Communication Port Anti-

thunder Protection

IEC61000-4-5 level 3

Operation 

Environment

Working Temperature

0℃~55℃

Storage Temperature

-40 ~85℃

Humidity(No-Condensing)

0~95%

Mechanical

Dimension(L×W×H)

63.2mm×82mm×25mm

Material

Aluminum

Color

Black

Weight

IPC:134g; SV:134g

连接接口

Trouble

 

Shooting

Please find the following solution when the device doesn't work

Please confirm if the installation according to factory installation request; 
Please confirm if the RJ45 cable order is in accordance with the EIA/TIA568A or 568B industry 
standards;
The maximum transmission distance depends on the signal source and cable quality, please do not 
exceed the maximum transmission distance; 
Please replace a failure device with a proper one to check if the device is broken;
If the problem still exists, please contact the factory. 

Products are subject to change without prior notice

Ethernet Extender

3

4

Table

 

1

:

Picture

 

1

:

Ethernet Extender

SV<->IPC 

cable

 

length

 L

Bandwidth

(Mbps)

75-5 

coaxial

 

cable

Cat5

100m

54.8

61

200m

54.6

53.7

300m

54.5

52.7

400m

54.4

51.3

500m

54.1

51

600m

53.9

47.1

700m

53.6

35.1

800m

53.1

/

 900m

52.2

/

1000m

50.3

/

1100m

48.5

/

1200m

47.2

/

Instruction: Test data in table 1 is required under a lab environment by the test 
method in picture 1. In actual case, there maybe some differences due to different 
cables and environments.

Ethernet 

switch

SV

IPC

100m

100m

Camera

L