连接接口
Specification
连接接口
Item
Description
Power
Power Supply
Power adapter supply
Voltage Range
DC 12V
Consumption
<2W
Ethernet Port
Parameter
Ethernet Port
EOC: 0--100Mbps Ethernet port:10/100Mbps;
transmission bandwidth changes based on
transmission distance, please refer to table 1
Transmission Distance
EOC coaxial cable: 0-1200m
EOC network cable: 0-700m
Transmission Medium
75-5 or above coaxial cable and Cat5e/6 cable
Ethernet
Exchange
Ethernet standard
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX
Ethernet delay
<1ms
Status
LED Indicator
Input/output ports:
power status(RJ45 yellow)
network signal transmission(RJ45 green);
EOC: indicate cable connection(RJ45 yellow/green)
Protection
Level
ESD
1a Contact Discharge level 3
1b Air Discharge level 3
IEC61000-4-2
Communication Port Anti-
thunder Protection
IEC61000-4-5 level 3
Operation
Environment
Working Temperature
0℃~55℃
Storage Temperature
-40 ~85℃
℃
Humidity(No-Condensing)
0~95%
Mechanical
Dimension(L×W×H)
63.2mm×82mm×25mm
Material
Aluminum
Color
Black
Weight
IPC:134g; SV:134g
连接接口
Trouble
Shooting
Please find the following solution when the device doesn't work
Please confirm if the installation according to factory installation request;
Please confirm if the RJ45 cable order is in accordance with the EIA/TIA568A or 568B industry
standards;
The maximum transmission distance depends on the signal source and cable quality, please do not
exceed the maximum transmission distance;
Please replace a failure device with a proper one to check if the device is broken;
If the problem still exists, please contact the factory.
Products are subject to change without prior notice
Ethernet Extender
3
4
Table
1
:
Picture
1
:
Ethernet Extender
SV<->IPC
cable
length
L
Bandwidth
(Mbps)
75-5
coaxial
cable
Cat5
100m
54.8
61
200m
54.6
53.7
300m
54.5
52.7
400m
54.4
51.3
500m
54.1
51
600m
53.9
47.1
700m
53.6
35.1
800m
53.1
/
900m
52.2
/
1000m
50.3
/
1100m
48.5
/
1200m
47.2
/
Instruction: Test data in table 1 is required under a lab environment by the test
method in picture 1. In actual case, there maybe some differences due to different
cables and environments.
Ethernet
switch
SV
IPC
100m
100m
Camera
L