Panasonic 

 
Note: 

Use of a different battery may have a detrimental effect on the 

product’s operation. Constant exposures to high or low humidity may 
reduce battery life.  

 
After installing or changing the  batteries, reinstall the  product’s top 
cover. Test your product by a wake up test.  
 

 

6.

 

Adding to the Control Panel 

Each  product  is programmed with a unique ID when manufactured. 
The unique ID is enrolled into the control panel at the time of 
installation,  allowing the product  to communicate with that specific 

control panel. 

 

A.

 

Log in to the Settings app with an Installer code.  

B.

 

In the Settings menu, tap Sensors & Zones > Add a Sensor/Zone. 

C.

 

Place the product in Search mode and prepare it to be added to 
the control panel (refer to the installation documentation for your 
sensors). Available sensors meet the following requirements: 

o

 

Defaulted. 

o

 

Not currently paired with another control panel device. 

o

 

Currently in Search mode. 

D.

 

At the Locating Wireless Sensors screen, tap Next. A Done button 
appears on the screen and the control panel searches for sensors 
that are available to be added. As sensors are found, a grayed 

icon appears for that sensor. 

E.

 

Fault each found sensor to pair it to the control panel. The icon for 
each sensor is undarkened as it is faulted and the control panel 

beeps. The sensor is paired to the control panel. 

F.

 

When all the sensors are found and paired, tap Stop. Any located 
sensors that were not paired  are released by the control panel 

and can be added later. The Wireless Sensors Located screen 
shows the number of wireless sensors found and paired. 

G.

 

Tap Next. The Configure Wireless Sensors screen shows icons of 
the sensors that were found and paired. 

H.

 

Touch each sensor icon to configure the corresponding product. 

The Add Sensor/Zone Modify screen appears. 

I.

 

To change the product Icon (if multiple options are available), tap 
the currently selected value. 

J.

 

Tap Next. The Add Sensor/Zone Modify screen appears. 

K.

 

To modify  a text field on the control panel, tap the field, use the 
onscreen keyboard to enter your changes, and tap Done to save 
your changes. 

L.

 

When all sensors are configured properly, tap Next in the 
Configure Wireless Sensors screen. 

M.

 

If all of the sensors have not been configured, the Modify screen 
appears for each sensor to let you review its details. Change the 
details as needed or tap Next to cycle through all the sensors. The 
sensors are marked as configured. 

 
 

7.

 

Testing the Product 

This  product  may be tested during install or at anytime. It is 
recommended the product be tested in place annually. This product is 
sealed. The cover is not removable. 

 

  WARNING:

  The control panel must be placed into sensor test 

mode while conducting any tests. Placing the control panel into sensor 

test mode for all testing helps to protect against false alarms and 
unintentional central station reporting. 
 

This product has three test methods:  

o

 

Wake Up Test.

 A hand clap should wake up the glass break 

detector.  

o

 

RF Communication Test. 

Tests the communication path with 

the control panel.  

o

 

Glass Break Functional Test. 

Tests the functional operation of 

the glass break sensing element.  

 

Wake Up Test 

To test the product locally is to clap your hands loudly above the sensor 
and verify that the LED blinks twice. This test verifies that the product is 
receiving power, and the microphone and circuit board are working 
properly. It does not trip the sensor. The hand clap is only a momentary 

test, so there is no significant affect on battery life. 
 

Note:

 Room acoustics can artificially extend the range of a glass-break 

sensor. The specified range of the sensor is set for worst-case 

conditions. While it may work at extended range, it can miss a 
minimum output break or room acoustics may change over time, 
bringing sensor range back into normal 2-foot (6 m) conditions. Do not 
exceed the rated range of the sensor, regardless of the tester results. 

 

RF Communication Test

 

This section provides general guidelines for testing the product with the 

control panel. For complete testing details, refer to the specific control 
panel documentation. 
 

A.

 

Be sure the product is normal operation. 

B.

 

Set the control panel to sensor test mode to prevent an alarm 
signal from being sent to the central-monitoring station if you 

have a monitored system. 

C.

 

To generate a test alarm, remove  the top cover generating a 

tamper alarm.  If the product is operating properly, an alarm 
message is sent to the control panel.  

D.

 

The control panel beeps and shows the number of RF packets 

received. 

E.

 

At the panel, exit sensor test mode. 

 

Glass Break Functional Test

 

The product is designed to detect the breaking of framed glass 

mounted in an outside wall. Testing the sensor with unframed lass, 
broken bottles, etc., may not trip the sensor. The sensor typically does 
not trip to glass breaking in the middle of the room. In rooms where 
multiple sounds can reflect and duplicate the glass-break frequency 

pattern. The Pattern Recognition Technology of the sensor ignores most 
false alarm sounds, including glass break testers. To test the sensor, 
use test mode. Test mode disables glass break pattern processing in 
upper and lower frequencies. The sensor is then listening only for the 

mid-range frequencies that the 5709C hand-held tester reproduces. It’s 
the mid-range frequencies that determine sensor range. 
 

Test Mode

 - To put the sensor in test mode, do the following: 

 

A.

 

Set the control panel to sensor test mode. 

B.

 

Use the 5709C handheld tester to put the sensor into test mode. 
Set the tester to tempered glass and hold the tester on top of the 

sensor. 

C.

 

Activate the tester. The sensor will alarm, then go into test mode 
for one minute. In test mode, the LED will blink continuously. To 

Содержание 5845GBW-OEM

Страница 1: ...e sensor is armed all day and all night The false alarm technology will be pushed to its limit in a 24 hour loop The sensor s false alarm immunity is best in rooms with only moderate noise Some sounds can duplicate the points on the glass break pattern the sensor detects The sensor may not consistently detect cracks in glass or bullets which break through the glass Glass break sensors should alway...

Страница 2: ...ocated in the front Remove the top cover by using a flat bladed tool in the screw location to pry open the top cover Locate the mounting location and drill holes in base per the mounting impression in the base Use the anchors and screws to secure the product to the mounting surface C Replace the product s top cover Snap the top onto the base Replace the screw into the front location 4 Basic Operat...

Страница 3: ...ntrol panel into sensor test mode for all testing helps to protect against false alarms and unintentional central station reporting This product has three test methods o Wake Up Test A hand clap should wake up the glass break detector o RF Communication Test Tests the communication path with the control panel o Glass Break Functional Test Tests the functional operation of the glass break sensing e...

Страница 4: ...l 20 ft 6 m conditions Do not exceed the rated range of the sensor regardless of what the tester shows 8 Defaulting the Detector This step should only be performed by a qualified service technician A Remove the top cover from the product B Remove the battery C Press the enrollment switch in the RF circuit inside the product and hold until you replace the batteries D Replace the battery while still...

Страница 5: ...trol panel The Sensor Diagnostic for Security Zone name appears as the system detects the current signal strength between the selected sensor and the control panel Trouble Refer to Section 13 for trouble shooting guidance Low Battery Replace the batteries per Section 5 Installing Replacing Battery 13 Troubleshooting Product does not power up properly or reports low battery o Be sure the battery is...

Страница 6: ...king properly AN ALARM SYSTEM IS NOT A SUBSTITUTE FOR INSURANCE Limited Warranty Edwards is a brand of UTC Fire Security The manufacturer warrants this product except batteries to be free from defects in material and workmanship under conditions of normal use for a term of 3 years from the date of manufacture During the warranty period if a UTC Fire Security product or any of its components become...

Страница 7: ...Manufacturer nor any other person is authorized to modify this warranty in any respect Repair or replacement as stated above is the exclusive remedy of the purchase hereunder This warranty gives you specific legal rights and you also have other rights which vary from state to state End of document ...

Отзывы: