Now type a test message using a POS keyboard.
Your message will appear in the
HyperTerminal window and on the RCD. The
RCD can display 2 lines of 20 characters
each. The display will wrap to line 2 after the
20
th
character. At the 20
th
character on line 2,
line 2 will move to line 1 position. The Esc
key will erase the display and return to line 1,
character 1 position.
The message will be displayed in the RCD.
To disconnect HyperTerminal from the RCD, click
the Disconnect icon and then exit
HyperTerminal. Any message in the RCD will
remain until the 3170 is restarted.
Install the Rear Cover’s screws and rubber plugs.
RS232 RCD Factory Settings
Baud rate = 9600, Word length = 8, Stop bits = 2, Parity = None. Refer
to the 3170 RCD Programming guide to change baud rates or parity.
You have completed the installation of the 3170 RCD. If you experience problems with any of
the components of the RCD, see the “Troubleshooting Procedures” section below.
Troubleshooting Procedures
The following table presents symptoms and solutions for problems potentially encountered when
installing the 3170 RCD.
Symptom
Solutions
The display does not
have power.
•
Ensure the RS232 connector is plugged into a COM port providing
+5VDC on pin 9. On the 3170 Workstation in a standard
configuration, COM2, COM3 and COM4 can provide power to the
RCD.
Meaningless characters
appear on the pole
display when I run my
application.
•
For RS232 Devices, check the baud-rate settings for the application
to ensure that they match the settings for the pole display.
Note:
Please call UTC RETAIL Technical Support at 800.349.0546, if you have any problems
not addressed in the Troubleshooting Procedures, or have questions about other
sections of this documentation.