Figure 9 

Figure 10

Figure 11

0  2  4  6 8  10  12  14  16 18  20  22 24  26  28 30m 

0m 

2m 

4m

6m

8m 

10m 

1.5m

-2°

TOP

MASK THIS SECTION 

OFF FOR PET ALLEY 

APPLICATIONS UP 

TO 30m

Note: 

EN50131-2-2 Grade 3 

compliance requires 3m mounting 

height and 0

º

 adjustment, or 1.5m 

mounting height and -2

º

 adjustment.

TOP

Long range 30m section

Short/ medium range 

6m to 20m section

24  26  28  30m 

0m 

2m 

4m

6m

8m 

10m 

0  2  4  6

8  10  12  14  16  18  20  22

3m

TOP

0  2  4  6 8  10  12  14  16  18  20  22 24  26  28  30m 

0m 

2m 

4m

6m

8m 

10m 

6m 

Note: 

This setup has not been tested 

to EN50131-2-2

Содержание interlogix DI601AM

Страница 1: ...EN DE ES FR IT NL PL PT SV Figure 1 DI601AM Outdoor PIR AM Detector Installation Sheet Figure 2 Figure 3 ...

Страница 2: ...Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 TOP ...

Страница 3: ...50131 2 2 Grade 3 compliance requires 3m mounting height and 0º adjustment or 1 5m mounting height and 2º adjustment TOP Long range 30m section Short medium range 6m to 20m section 0 24 26 28 30m 0m 2m 4m 6m 8m 10m 0 2 4 6 8 10 12 14 16 18 20 22 3m TOP 9 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m 0m 2m 4m 6m 8m 10m 6m Note This setup has not been tested to EN50131 2 2 ...

Страница 4: ...4m 2m 4m 70 Figure 14 45 MASK THIS SECTION OFF FOR CURTAIN COVERAGE APPLICATIONS 0 2 4 6 8 10 12 14 16m 0 2m 4m 6m 8m 10m 0 2 4 6 8 0 2m 4m 6m 8m 10m 6m 70 0 2m 4m 6m 8m 10m 12m 2m 4m 6m 8m 10m 12m 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m ...

Страница 5: ... item 2 Jt Jumper to set EOL resistor value for standby Figure 15a item 3 Jf Jumper to set EOL resistor value for fault Figure 15a item 4 Ja Jt J TEOL Jf alarm n c tamper fault alarm n o Ja 1 2 Figure 15a 3 4 0V 12V ALARM N O ALARM N O TAMPER TAMPER ALARM N C ALARM N C FAULT A M FAULT A M REMOTE TEST REMOTE LED DEOL TEOL ...

Страница 6: ...Inf OPEN CIRCUIT EXAMPLE USING 4K7 TAMPER 4K7 ALARM AND 10K FAULT A M RESISTORS ALSO TEOL JUMPER SELECTED REMOVE ALL JUMPERS FOR ISOLATED OUTPUTS Single zone TEOL Calculation Event Default Ohm CALCULATION TAMPER SHORT 0 CLOSED CIRCUIT STANDBY 4K7 Rt ALARM 9K4 Rt Ra TAMPER OPEN Inf OPEN CIRCUIT EXAMPLE USING 4K7 TAMPER AND 4K7 ALARM RESISTORS REMOVE ALL JUMPERS FOR ISOLATED OUTPUTS Single zone DEOL...

Страница 7: ...igure 2 3 Use a razor knife to open a rubber seal to allow the cabling into the unit see Figure 4 Feed standard eight core or 12 core alarm cable though the wall and directly into the cable entry Bare the wires and connect to the top PCB terminal block Figure 15 Caution Do not allow the cable to be trapped between the rear gasket and the mounting surface as this may cause water ingress For surface...

Страница 8: ...edges of the pan and tilt module and press on the lens to click it into place Always replace the lens the correct way up to ensure exact beam pattern coverage The top of the lens is marked TOP as shown in Figure 7 There is a locating notch on the top of the pan and tilt module that locates into the cut out on the top of the lens Table 2 below summarizes typical masking configurations for use when ...

Страница 9: ... CAUTION The range of the detector increases without the protective front cover Therefore the front cover must be fitted to establish the correct beam pattern Use Table 3 to adjust the range as necessary Pan and tilt the lens module over the field of view to obtain the correct coverage area See Figure 18 Fault Anti Mask Circuit Fault Anti Mask technology prevents deliberate disabling of the detect...

Страница 10: ... memory Walk test Output test mode with LED indication Option to disable LEDs Operating temperature 30 to 65 C Housing High impact ABS plastic with HDPE cover UV stabilized Dimensions W x H x D 125 x 175 x 130 mm Weight 348g Net 534 g Gross Mounting height Variable up to 6 m Optimum height 3 m for full range Regulatory information Manufacturer UTC Fire Security Americas Corporation Inc 1275 Red Fo...