Specifications

Detection range

Programmable: 10 m, 20 m 

or 30 m 

Coverage 

10 to 70° detection angle, 30 

x 24 m coverage max.

Adjustment  

-60° to +60° pan, tilt +45°

Fresnel lens

28 zones for each detection 

element, which can be 

masked with the curtain 

sliders

Customized optics

Double silicon shielded quad 

element eliminates 50,000 

Lux of white light

LEDs

Top PCB

Sensor PCB

Red: Programming LED

Blue: Detection alarm
 
Red(small): Anti-mask alarm

Infrared: Walk tester 
communication

Outputs

NO

NC

Silent, solid state, 

magnetically immune. 

Volt free relay, signal contact 

24 VAC/DC at 50 mA with an 

integral 25 Ω series resistor.

Alarm time 5 seconds.

Volt free relay, signal contact 

24 VAC/DC at 50 mA with an 

integral 25 Ω series resistor.

Alarm time 5 seconds.

Fault/Mask

Volt free relay, signal contact 

24 VAC/DC at 50 mA with an 

integral 25 Ω series resistor

Power input

10 to 15 V DC

Current

16 mA (12 V nominal) 

Standby 27 mA MAX

Pulse count

1 or 2

Temperature 

compensation 

Analogue (thermistor) and 

digital sensitivity adjustment

Control 

Digital microprocessor with 

non-volatile memory

Walk test

Output test mode with LED 

indication. Option to disable 

LEDs.

Operating temperature

−30 to +65°C

Housing

High impact ABS plastic with 

HDPE cover, UV stabilized

Dimensions W x H x D

125 x 175 x 130 mm

Weight

348g Net, 534 g Gross 

Mounting height

Variable up to 6 m 

Optimum height 3 m for full 

range

Regulatory information

Manufacturer 

UTC Fire & Security Americas 

Corporation, Inc.

1275 Red Fox Rd., Arden Hills, MN 

55112-6943, USA 

Authorized EU manufacturing 

representative:

UTC Fire & Security B.V.

Kelvinstraat 7, 6003 DH Weert, 

Netherlands

Certification

EN50130 

EN50131

EN50130-5

EN50131-2-2, Grade 3, Class IV

Certified by Telefication B.V

Note: EN50131-2-2 compliant only 

when mounted at 1.5m and 3m.

Environmental class

IP65

This product meets the 

environmental requirements of 

EN50130-5.

2002/96/EC (WEEE directive): 

Products marked with this symbol 

cannot be disposed of as unsorted 

municipal waste in the European 

Union. For proper recycling, return 

this product to your local supplier 

upon the purchase of equivalent 

new equipment, or dispose of it 

at designated collection points. 

For more information see: www.

recyclethis.info.

Contact information

www.utcfireandsecurity.com or www.interlogix.com.

For customer support, see www.interlogix.com/customer-

support

Содержание interlogix DI601AM

Страница 1: ...EN DE ES FR IT NL PL PT SV Figure 1 DI601AM Outdoor PIR AM Detector Installation Sheet Figure 2 Figure 3 ...

Страница 2: ...Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 TOP ...

Страница 3: ...50131 2 2 Grade 3 compliance requires 3m mounting height and 0º adjustment or 1 5m mounting height and 2º adjustment TOP Long range 30m section Short medium range 6m to 20m section 0 24 26 28 30m 0m 2m 4m 6m 8m 10m 0 2 4 6 8 10 12 14 16 18 20 22 3m TOP 9 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m 0m 2m 4m 6m 8m 10m 6m Note This setup has not been tested to EN50131 2 2 ...

Страница 4: ...4m 2m 4m 70 Figure 14 45 MASK THIS SECTION OFF FOR CURTAIN COVERAGE APPLICATIONS 0 2 4 6 8 10 12 14 16m 0 2m 4m 6m 8m 10m 0 2 4 6 8 0 2m 4m 6m 8m 10m 6m 70 0 2m 4m 6m 8m 10m 12m 2m 4m 6m 8m 10m 12m 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30m ...

Страница 5: ... item 2 Jt Jumper to set EOL resistor value for standby Figure 15a item 3 Jf Jumper to set EOL resistor value for fault Figure 15a item 4 Ja Jt J TEOL Jf alarm n c tamper fault alarm n o Ja 1 2 Figure 15a 3 4 0V 12V ALARM N O ALARM N O TAMPER TAMPER ALARM N C ALARM N C FAULT A M FAULT A M REMOTE TEST REMOTE LED DEOL TEOL ...

Страница 6: ...Inf OPEN CIRCUIT EXAMPLE USING 4K7 TAMPER 4K7 ALARM AND 10K FAULT A M RESISTORS ALSO TEOL JUMPER SELECTED REMOVE ALL JUMPERS FOR ISOLATED OUTPUTS Single zone TEOL Calculation Event Default Ohm CALCULATION TAMPER SHORT 0 CLOSED CIRCUIT STANDBY 4K7 Rt ALARM 9K4 Rt Ra TAMPER OPEN Inf OPEN CIRCUIT EXAMPLE USING 4K7 TAMPER AND 4K7 ALARM RESISTORS REMOVE ALL JUMPERS FOR ISOLATED OUTPUTS Single zone DEOL...

Страница 7: ...igure 2 3 Use a razor knife to open a rubber seal to allow the cabling into the unit see Figure 4 Feed standard eight core or 12 core alarm cable though the wall and directly into the cable entry Bare the wires and connect to the top PCB terminal block Figure 15 Caution Do not allow the cable to be trapped between the rear gasket and the mounting surface as this may cause water ingress For surface...

Страница 8: ...edges of the pan and tilt module and press on the lens to click it into place Always replace the lens the correct way up to ensure exact beam pattern coverage The top of the lens is marked TOP as shown in Figure 7 There is a locating notch on the top of the pan and tilt module that locates into the cut out on the top of the lens Table 2 below summarizes typical masking configurations for use when ...

Страница 9: ... CAUTION The range of the detector increases without the protective front cover Therefore the front cover must be fitted to establish the correct beam pattern Use Table 3 to adjust the range as necessary Pan and tilt the lens module over the field of view to obtain the correct coverage area See Figure 18 Fault Anti Mask Circuit Fault Anti Mask technology prevents deliberate disabling of the detect...

Страница 10: ... memory Walk test Output test mode with LED indication Option to disable LEDs Operating temperature 30 to 65 C Housing High impact ABS plastic with HDPE cover UV stabilized Dimensions W x H x D 125 x 175 x 130 mm Weight 348g Net 534 g Gross Mounting height Variable up to 6 m Optimum height 3 m for full range Regulatory information Manufacturer UTC Fire Security Americas Corporation Inc 1275 Red Fo...

Отзывы: