Chapter 2: Installation
Concord 4 Installation Manual
9
Device
Max. wire
length to
panel
Standby mA
draw
Alarm mA draw
SuperBus 2000 energy saver module
22 ga.: 1,600
ft.
18 ga.: 4,000
ft.
20 mA
20 mA
SuperBus 2000 automation module
22 ga.: 1,500
ft.
18 ga.: 4,000
ft.
30 mA
35 mA
SuperBus 2000 wireless cellular gateway
22 ga.: 40 ft.
18 ga.: 90 ft.
65 mA
1600 mA
Interrogator 200
22 ga.: 3,200
ft.
18 ga.: 4,500
ft.
10 mA
10 mA
Interrogator AVM
22 ga.: 110 ft.
18 ga.: 260 ft.
45 mA
300 mA
Two-wire smoke detectors (ESL 429AT,
429C, 429CT, 521B, 521BXT, 521NCSXT
22 ga.: 330 ft.
18 ga.: 330 ft.
70 µA
60 mA
Two-wire smoke detectors (system sensor
2400, 2400TH)
22 ga.: 330 ft.
18 ga.: 330 ft.
120 µA
80 mA
Hardwired interior siren (13-949)
22 ga.: 750 ft.
18 ga.: 1,500
ft.
0 mA
85 mA
Piezo dynamic exterior siren (13-950)
22 ga.: 750 ft.
18 ga.: 1,500
ft.
0 mA
150 mA
Speaker siren (60-528 or 13-060)
18 ga.: 100 ft. 0 mA
500 mA
*Maximum current draw for the SnapCards does not include the load which may be applied to
their auxiliary DC supply.
Table 5 below describes the total system wire lengths allowed for all SuperBus
2000 devices when installing systems using unshielded or shielded cable. After
determining panel location, run all necessary wires to that location using the
information in Table 6 on page 10.
Table 5: Wire lengths
Wire type
Total system wire
18-gauge, unshielded
18-gauge, shielded
4,000 ft.
3,000 ft.