PROBLEM
Hard water,
salt level does not change
Hard water
Hard water
from time to time
Salt bridge was formed
Increased water consumption
Test with a broom handle.
Break the bridge
and remove its pieces
Check and re-set regeneration time
Regeneration mode was not set
Improper regeneration time
Float jammed
Feedwater hardness has increased
Injector plugged
Lack of upper basket
The use of hot water during
regeneration process
Set regeneration mode.
Carry out manual regeneration.
Check and re-set regeneration time
Disassemble and clean parts
Check and re-set regeneration time
Disassemble and clean parts
Contact your local dealer
Do not use hot water during
regeneration proces
POSSIBLE CAUSE
POSSIBLE SOLUTION
Excessive salt consumption
Improper salt setting
Check salt usage and salt setting
Low water pressure
Inlet of control plugged
Sediments in feeding line
Sediments in the soener
Remove piston and clean control
Clean the installation
Clean control or conduct chemical
cleaning. Increase regeneration
frequency
Resin flushed to drain
Resin in the installation
Air in water system
Cracked resin tank
Inappropriate restrictor or DLFC
Broken tank elements
Broken or incorrectly assembled
upper basket
Assure the well system has proper
air eliminator control, check for dry
well condition
Seal or replace the tank
DLFC check restrictor
Replace broken pieces
Check basket assembly,
contact your local dealer
Excess water
in brine tank
Injector plugged
Foreign material in brine tank
Plugged drain line flow control (DLFC)
Clean or replace injector
Clean the tank
Clean the parts
Soener fails
to draw brine
Plugged DLFC
Plugged injector
Low water pressure
Internal control leak
Clean flow control
Clean injector
Increase water pressure to 1,7 bar
Replace gaskets, spacers
and/or piston
Drain flows continuously
Control cycles continuously
Inappropriate settings
Broken gear
Foreign material in control
Internal control leak
Replace gaskets, spacers
and/or piston
Check and correct the settings
Replace broken parts
Clean control
Leak at distributor tube
Exhausted ion exchange resin
Regenerate the resin
Make sure distributor tube is not
cracked. Check o-ring and tube pilot.
Replace faulty parts