VENTING INTO A fIREPLACE

Many  people  may  wish  to  convert  an  existing 

fireplace to heater use.  Usually, safe connection 

of stovepipe to a masonry chimney requires more 

effort than connection to a prefabricated chimney.  

The fireplace must be tightly closed and sealed 

at  the  damper  in  the  flue.    Good  sealants  are 

high-temperature  caulking,  ceramic  wool,  and 

furnace cement.  Always remember to inspect 

the masonry chimney and fireplace.  If necessary, 

clean the flue and smoke shelf before beginning 

your installation.  Install the heater into the fire-

place so that the system can be dismantled for 

cleaning and inspection.

Before deciding to convert your fireplace, keep in 

mind that some fireplaces and existing chimneys 

are unsafe.  They must be structurally sound, and 

the flue liner must be in good condition.  Do not 

use a chimney if it is unlined (should have a fire 

clay tile liner to protect brickwork).  Have it relined 

professionally.  Clearances to combustibles are 

explained  in  the  previous  section  on  masonry 

chimneys.  If you have any questions regarding 

the condition of the chimney, consult a qualified 

engineer, competent mason, or knowledgeable 

inspector.

CAUTION:

NOT ALL FIREPLACES ARE

SUITABLE FOR INSTALLATION

OF A WOOD HEATER.

Many prefabricated fireplaces fall into the "zero-

clearance fireplace" category.  This is a factory-

built metal fireplace with multi-layered construc-

tion.  It is designed to provide enough insulation 

and/or  air  cooling  so  that  the  base,  back  and 

sides can be safely placed in direct contact with 

combustible  floors  and  walls.    Although  many 

prefabricated  fireplaces  have  been  tested  by 

nationally  recognized  organizations  for  use  as 

fireplaces, they have not been tested to accept 

heaters.  In fact, their use as such may void the 

manufacturer's warranty.

Steel-lined fireplaces, on the other hand, can be 

used with heaters.  These units use a 1/4-inch 

firebox liner and an air chamber in connection with 

8 inches of masonry to meet code.  They contain all 

the essential parts of a fireplace, firebox, damper, 

throat, smoke shelf, and smoke chamber.  Many 

of them look exactly like a masonry fireplace and 

must be checked closely for above requirements 

before installing a wood heater into them.

Another method frequently used by some people 

is to vent the heater directly into the fireplace.  

This does not meet code since the heater is be-

ing vented into another appliance - the fireplace.  

This method should not be attempted because 

combustion products will deposit and build up in 

the firebox  or fireplace.  Be certain not to install 

a hazard in your house.  You will void your war-

ranty with this installation.

Содержание King 2007B

Страница 1: ...a CAUTION Read All Instructions Carefully BeforeStartingTheInstallation or Operating This Heater Improper Installation Could Void Your Warranty EXEMPT PER EPA METHOD 28A TESTED TO UL 1482 SAVE THIS MANUAL FOR FUTURE REFERENCE THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE Pt N...

Страница 2: ...ng Rule or Tape Measure Drill Hand or Electric Drill Bit 1 8 Dia For Sheet Metal Screws 5 16 Nut Driver or 5 16 Socket w Ratchet Screw Driver Blade Type Gloves Safety Glasses MATERIALS 6 Pipe 6 Elbow Collar and Thimble As Required 24 gauge min 1 2 Sheet Metal Screws No 10A x 1 2 6 Inside Diameter Underwriters Laboratories UL Listed Residential SolidFuelFactory BuiltTriplewallChimneyorExitingMasonr...

Страница 3: ...ne to use this heater who is unfamiliar with the correct operation of the heater 12 ForadditionalinformationonusingyourRoomHeatersafely obtain a copy of the National Fire Protection Association NFPA publication Chimneys Fireplaces and Solid Fuel Burning Appliances NFPA No 211 USA CAUTION Do not touch the metal or glass surfaces of the heater until it has thoroughly cooled safety rules 13 Disposal ...

Страница 4: ... Figures 2 3 4 You should have at least the clearances shown from the heater and the connector pipe to combustible surfaces If you have a solid brick or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall LOCATING THE ROOM HEATER AS A LOCATION IS SELECTED KEEP THE FOLLOWING IN MIND MINI...

Страница 5: ... comes equipped with a cast iron flue collar with holes to mount the solid damper as shown below Flue Collar 40292 Solid Damper 40398 5 16 18 x 1 1 2 Bolts 3 req Weld Tab 3 req Gasket MOUNTING CAST IRON FLUE COLLAR ...

Страница 6: ...4 ASSEMBLY INSTRUCTIONS Step 1 THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION With pliers cut the 6 micro joints and remove panel Note Discard the panel Step 2 Fix the assembly to the back of the stove with the four screws provided THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE DO NOT R...

Страница 7: ...vent back puffing smoke spillage and to maximize performance Chimneysperformtwofunctions oneofwhich is apparent The chimney provides a means for exhausting smoke and flue gases result ing from combustion of the fuel Secondarily though the chimney provides Draft which allows oxygen to be continuously introduced intotheappliance sothatpropercombustionis possible As ofApril 1 1987 all wood heaters an...

Страница 8: ...TION OF A WOOD HEATER Many prefabricated fireplaces fall into the zero clearance fireplace category This is a factory built metal fireplace with multi layered construc tion It is designed to provide enough insulation and or air cooling so that the base back and sides can be safely placed in direct contact with combustible floors and walls Although many prefabricated fireplaces have been tested by ...

Страница 9: ...ch as a 6 flue outlet requires a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond an 8 diameter Masonry chimneys built of concrete blocks with or without flue liners do not meet modern build ing codes A solid fuel appliance must not be joined to a chimney flue which is connected to another appliance burning other fuels VENTING INTO A MASONRY CHIMNEY If ...

Страница 10: ...ing sure that the thimble is flush with the inner flue lining secure the thimble in place with refractory mortar The thimble should be surrounded on all sides with 8 inches of brickwork solid masonry units or 24 inches of stone Install the stovepipe as far as possible into the thimble but not past the inside of the flue lining Thereshouldbeasmallairspace approximately 1 2 inch between the stovepip...

Страница 11: ... 4 The pipe cannot extend into the chimney flue Fig 8 5 Seal each connector pipe joint with furnace cement Also seal the pipe at the chimney 6 Use 3 sheet metal screws at each joint to make the piping rigid 7 It is recommended that no more than two 2 90 degree bends be used in the stove pipe installation as more than two 2 may decrease the amount of draw and possibly cause smoke spillage 8 The chi...

Страница 12: ...imney like water over a dam beating down the smoke The top of the chimney should be at least 3 feet above the roof and be at least to 2 feet higher than any point of the roof within 10 feet chimney maintenance Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense...

Страница 13: ... Nickel 1 8 AC09185 Door Barrell Roller Ball Pin Assy 1 9 891108 Door Glass 1 N S 88087 Door Glass Gasket 6 ft 10 891114 Top Window Bracket 4 11 PL02715 Bottom Window Bracket 1 12 83033 Machine Screw 8 32 X 12 13 891213 Hinge Pad 1 N S 83274 Nut 3 8 16 2 N S 83045A Washer 2 14 25298 Baffle 1 15 891759 Hearth Trim Nickel 1 16 83431 Weld Tab 3 17 25307 Flue Collar 1 18 88042 Gasket Flue Collar 2 ft ...

Страница 14: ...TION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BE FORE ATTEMPTING ANY MAINTENANCE BRICKPLACEMENT TOPINSIDEVIEWOFFIREBOX 1 INSERT RIGHT LEFT SIDE FIREBRICK AS SHOWN 2 INSERT REAR FIREBRICK AS SHOWN 3 INSERTBOTTOM1 2FIREBRICKANDASHDUMPCOVER AS SHOWN 1 2 BRICK 1 2 BRICK ...

Страница 15: ...combustible container Replace the ash pan after dumping the ashes ASHES SHOULD BE PLACED IN A METAL CONTAINER WITH A TIGHT FITTING LID THE CLOSED CONTAINER OF ASHES SHOULD BE PLACED ON A NONCOMBUSTIBLE FLOOR OR ON THE GROUND WELL AWAY FROM ALL COMBUSTIBLE MATERIALS PENDING FINAL DISPOSAL IF THE ASHES ARE DISPOSED OF BY BURIAL IN SOIL OR OTHERWISE LOCALLY DISPERSED THEY SHOULD BE RETAINED IN THE CL...

Страница 16: ...umber which is on the nameplate attached to the heater when ordering repair parts always give the following informa tion as shown in this list 1 The part number 2 the part description 3 the model number 2007B 4 the serial number ____________________ how to order repair parts united states stove company 227 industrial park road p o box 151 south pittsburg tn 37380 423 837 2100 WWW USSTOVE COM C S S...

Отзывы: