USSC King 2007B Скачать руководство пользователя страница 5

5

This heater comes equipped with a cast-iron flue collar with holes to mount the solid damper as 

shown below.

Flue Collar  -  40292

Solid Damper  -  40398

5/16-18 x 1-1/2" Bolts (3 req.)

Weld Tab (3 req.)

Gasket

MOUNTING CAST-IRON fLUE COLLAR

Содержание King 2007B

Страница 1: ...a CAUTION Read All Instructions Carefully BeforeStartingTheInstallation or Operating This Heater Improper Installation Could Void Your Warranty EXEMPT PER EPA METHOD 28A TESTED TO UL 1482 SAVE THIS MANUAL FOR FUTURE REFERENCE THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE Pt N...

Страница 2: ...ng Rule or Tape Measure Drill Hand or Electric Drill Bit 1 8 Dia For Sheet Metal Screws 5 16 Nut Driver or 5 16 Socket w Ratchet Screw Driver Blade Type Gloves Safety Glasses MATERIALS 6 Pipe 6 Elbow Collar and Thimble As Required 24 gauge min 1 2 Sheet Metal Screws No 10A x 1 2 6 Inside Diameter Underwriters Laboratories UL Listed Residential SolidFuelFactory BuiltTriplewallChimneyorExitingMasonr...

Страница 3: ...ne to use this heater who is unfamiliar with the correct operation of the heater 12 ForadditionalinformationonusingyourRoomHeatersafely obtain a copy of the National Fire Protection Association NFPA publication Chimneys Fireplaces and Solid Fuel Burning Appliances NFPA No 211 USA CAUTION Do not touch the metal or glass surfaces of the heater until it has thoroughly cooled safety rules 13 Disposal ...

Страница 4: ... Figures 2 3 4 You should have at least the clearances shown from the heater and the connector pipe to combustible surfaces If you have a solid brick or stone wall behind your heater you can place the heater as close as you wish to the wall If the wall is only faced with brick or stone treat it as a combustible wall LOCATING THE ROOM HEATER AS A LOCATION IS SELECTED KEEP THE FOLLOWING IN MIND MINI...

Страница 5: ... comes equipped with a cast iron flue collar with holes to mount the solid damper as shown below Flue Collar 40292 Solid Damper 40398 5 16 18 x 1 1 2 Bolts 3 req Weld Tab 3 req Gasket MOUNTING CAST IRON FLUE COLLAR ...

Страница 6: ...4 ASSEMBLY INSTRUCTIONS Step 1 THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BEFORE ATTEMPTING THE INSTALLATION With pliers cut the 6 micro joints and remove panel Note Discard the panel Step 2 Fix the assembly to the back of the stove with the four screws provided THE BLOWER ASSEMBLY IS INTENDED FOR USE ONLY WITH A STOVE THAT IS MARKED TO INDICATE SUCH USE DO NOT R...

Страница 7: ...vent back puffing smoke spillage and to maximize performance Chimneysperformtwofunctions oneofwhich is apparent The chimney provides a means for exhausting smoke and flue gases result ing from combustion of the fuel Secondarily though the chimney provides Draft which allows oxygen to be continuously introduced intotheappliance sothatpropercombustionis possible As ofApril 1 1987 all wood heaters an...

Страница 8: ...TION OF A WOOD HEATER Many prefabricated fireplaces fall into the zero clearance fireplace category This is a factory built metal fireplace with multi layered construc tion It is designed to provide enough insulation and or air cooling so that the base back and sides can be safely placed in direct contact with combustible floors and walls Although many prefabricated fireplaces have been tested by ...

Страница 9: ...ch as a 6 flue outlet requires a 6 diameter for optimum drafting but can function well with an 8 but becomes borderline beyond an 8 diameter Masonry chimneys built of concrete blocks with or without flue liners do not meet modern build ing codes A solid fuel appliance must not be joined to a chimney flue which is connected to another appliance burning other fuels VENTING INTO A MASONRY CHIMNEY If ...

Страница 10: ...ing sure that the thimble is flush with the inner flue lining secure the thimble in place with refractory mortar The thimble should be surrounded on all sides with 8 inches of brickwork solid masonry units or 24 inches of stone Install the stovepipe as far as possible into the thimble but not past the inside of the flue lining Thereshouldbeasmallairspace approximately 1 2 inch between the stovepip...

Страница 11: ... 4 The pipe cannot extend into the chimney flue Fig 8 5 Seal each connector pipe joint with furnace cement Also seal the pipe at the chimney 6 Use 3 sheet metal screws at each joint to make the piping rigid 7 It is recommended that no more than two 2 90 degree bends be used in the stove pipe installation as more than two 2 may decrease the amount of draw and possibly cause smoke spillage 8 The chi...

Страница 12: ...imney like water over a dam beating down the smoke The top of the chimney should be at least 3 feet above the roof and be at least to 2 feet higher than any point of the roof within 10 feet chimney maintenance Creosote Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creosote vapors condense...

Страница 13: ... Nickel 1 8 AC09185 Door Barrell Roller Ball Pin Assy 1 9 891108 Door Glass 1 N S 88087 Door Glass Gasket 6 ft 10 891114 Top Window Bracket 4 11 PL02715 Bottom Window Bracket 1 12 83033 Machine Screw 8 32 X 12 13 891213 Hinge Pad 1 N S 83274 Nut 3 8 16 2 N S 83045A Washer 2 14 25298 Baffle 1 15 891759 Hearth Trim Nickel 1 16 83431 Weld Tab 3 17 25307 Flue Collar 1 18 88042 Gasket Flue Collar 2 ft ...

Страница 14: ...TION THE BLOWER ASSEMBLY MUST BE DISCONNECTED FROM THE SOURCE OF ELECTRICAL SUPPLY BE FORE ATTEMPTING ANY MAINTENANCE BRICKPLACEMENT TOPINSIDEVIEWOFFIREBOX 1 INSERT RIGHT LEFT SIDE FIREBRICK AS SHOWN 2 INSERT REAR FIREBRICK AS SHOWN 3 INSERTBOTTOM1 2FIREBRICKANDASHDUMPCOVER AS SHOWN 1 2 BRICK 1 2 BRICK ...

Страница 15: ...combustible container Replace the ash pan after dumping the ashes ASHES SHOULD BE PLACED IN A METAL CONTAINER WITH A TIGHT FITTING LID THE CLOSED CONTAINER OF ASHES SHOULD BE PLACED ON A NONCOMBUSTIBLE FLOOR OR ON THE GROUND WELL AWAY FROM ALL COMBUSTIBLE MATERIALS PENDING FINAL DISPOSAL IF THE ASHES ARE DISPOSED OF BY BURIAL IN SOIL OR OTHERWISE LOCALLY DISPERSED THEY SHOULD BE RETAINED IN THE CL...

Страница 16: ...umber which is on the nameplate attached to the heater when ordering repair parts always give the following informa tion as shown in this list 1 The part number 2 the part description 3 the model number 2007B 4 the serial number ____________________ how to order repair parts united states stove company 227 industrial park road p o box 151 south pittsburg tn 37380 423 837 2100 WWW USSTOVE COM C S S...

Отзывы: