background image

CONGRATULATIONS!

You've purchased one of America's Finest Wood Burning Heaters. By
heating with wood and coal, you're helping CONSERVE AMERICA'S
ENERGY!
Wood is our Renewable Energy Resource.  Please do your part to
preserve our wood supply.  Plant at least one tree each year.  Future
generations will thank you.

NOTE:  YOUR UNIT MUST BE INSTALLED BY A QUALIFIED
FURNACE INSTALLER.  IMPROPER INSTALLATION COULD
VOID YOUR WARRANTY!

NOTE: (See Page 5, First Paragraph)

Tools And Materials Needed

TOOLS                                                  MATERIALS
Pencil

6" Pipe, 6" Elbow, Collar and Thimble

6 Foot Folding Rule or Tape

as required (24 gauge min.)

Tin Snips

1/2" Sheet Metal Screws

Drill, (Hand or Electric)

6" Inside diameter Listed Residential Type

Drill bit, - 1/8" dia.

or Building Heating Appliance Chimney

(For Sheet Metal Screws)

or existing masonry chimney (See Page 8)

Screw Driver (Blade-Type)

Electrical Wiring

Gloves

6" Draft Regulator

Sabre Saw

1/2" Conduit (Conduit Connectors)

5/16" Nut Driver or

Furnace Cement

5/16" Socket w/Ratchet

Manufacturer Recommends:

Safety Glasses

Rutland Black-Code 78 or Equivalent

Plenum and Duct work as required.

2

Содержание Hotblast 1321

Страница 1: ...UTURE REFERENCE FOR PARALLEL INSTALLATION WITH EXISTING AIR GAS OR OIL FIRED FURNACE OR FOR INSTALLATION AS A CENTRAL FURNACE DO NOT USE THIS FURNACE IN A MOBILE HOME OR TRAILER UNITED STATES STOVE COMPANY 227 Industrial Park Rd P O Box 151 South Pittsburg TN 37380 423 837 2100 851153A 10 96 WARNOCKHERSEY R MODEL 1321 Owners Manual SOLID FUEL WARM AIR FURNACE H TBL ST A O COMPANY U NITED STATES ST...

Страница 2: ...t Paragraph Tools And Materials Needed TOOLS MATERIALS Pencil 6 Pipe 6 Elbow Collar and Thimble 6 Foot Folding Rule or Tape as required 24 gauge min Tin Snips 1 2 Sheet Metal Screws Drill Hand or Electric 6 Inside diameter Listed Residential Type Drill bit 1 8 dia or Building Heating Appliance Chimney For Sheet Metal Screws or existing masonry chimney See Page 8 Screw Driver Blade Type Electrical ...

Страница 3: ...l or other combustible material within the marked installation clearances DO NOT store fuels paints thinners flammable liquids or other highly volatile substances in the furnace room CAUTION HOT SURFACES Keep children away Do not touch during operation SAFETY NOTICE If this heater is not properly installed a house fire may result For your safety follow the installation directions Contact local bui...

Страница 4: ...a copy of the National Fire Protection Association NFPA publication Chimneys Fireplaces and Solid Fuel Burning Appliances NFPA 211 The address of the NFPA is Batterymarch Park Quincy MA 02269 11 Keep the ash pit section free of excess ashes Do not allow ashes to stack higher than the sides of the ash pan 12 DISPOSAL OF ASHES Place ashes in a metal container with a tight fitting lid Keep the closed...

Страница 5: ...rnace may be installed in conjunction with a properly operat ing central furnace that is listed or certified in accordance with nationally recognized safety standards and equipped with the required con trols and other safety features and which has been installed in accordance with appropriate standards of the National Fire Protection Asso ciation with installation clearances specified in the furna...

Страница 6: ...1321 DIMENSIONS Shown in Fig 1 are the dimensions of the furnace 6 22 5 16 36 5 8 28 3 4 2 34 37 5 8 Fig 1 ...

Страница 7: ... connector pipe to backwall 18 Hot air ducts to combustibles 6 NOTE Install only on a noncombustible floor REFER TO FIG 2 3 3 Place the furnace on a noncombustible floor 4 Check figures 2 and 3 Be sure you have the clearances shown from the fur nace and the connector pipe to combus tible surfaces If you have a solid brick or stone wall behind your heater you can place the furnace as close as you w...

Страница 8: ... for a furnace must not be used to ventilate the cellar or basement If there is a cleanout opening at the base of the chimney close it tightly LISTED FACTORY BUILT CHIMNEY Carefully follow chimney manufacturer s instructions Use only a Listed Residential Type or Building Heating Appliance Chimney If your chimney starts at the ceiling Fig 5 you will need enough 6 pipe to reach the ceiling The top o...

Страница 9: ...tion for a barometric draft regulator between the furnace and the chimney fig 4 5 7 The barometric draft regulator must be installed in the same room same pressure zone as the furnace 8 Install the barometric draft regulator strictly in accordance with the instructions that are provided with the barometric draft regulator 9 A solid damper must be used in the chimney connecting pipes between the fl...

Страница 10: ...ywell Fan Limit Control on rear of cabinet as shown in Fig 8 NOTE Remove cover of Fan Limit control for access to screw holes 4 Remove blower from carton and inspect for damage Remove cover from 4 junction box on rear of furnace See Fig 8 5 Attach clip nuts to blower opening on rear of furnace as shown Install blower and gasket using 1 4 20x3 4 bolts provided 6 Complete all wiring in 4 junction bo...

Страница 11: ... Honeywell LIMIT SWITCH R1 R2 G W 110 VAC 60 HZ GROUND G B W ELECTRICAL JUNCTION BOX M1 M2 BLOWER MOTOR IMPORTANT POWER SUPPLY WIRING MUST NOT BE LESS THAN 90 CENTIGRADE POWER CORD WIRE COLOR CODE G GREEN GROUND B BLACK POWER SUPPLY W WHITE POWER SUPPLY R1 WHITE FAN CONTROL R2 BLACK FAN CONTROL M1 BLACK FAN CONTROL M2 WHITE BLOWER MOTOR Fig 9 ...

Страница 12: ...on must be made only on a noncom bustible floor d Install the smoke pipe connector to the chim ney with 26 gauge pipe and elbows to be pur chased separately maintaining the proper clear ances for the specific model Seal the spoke pipe in the chimney with furnace cement The chimney connector shall be securely supported and joints fastened with sheet metal screws or rivets e Install 8 diameter heat ...

Страница 13: ... Back Panel Flue Collar Gasket FlueCollar FlueCollarRing Cabinet Top Panel FireboxWeldment Feed Door Assembly 40340 Ash Door Assembly 40289 Firebrick Grate ThermostatCover DamperDoor Thermostat Assembly CabinetBottom DoorHandle FeedDoor DoorHandle AshDoor FrontFireboxLiner SmokeCurtain Brass Spring Handle DamperDoorPin Ash Pan DoorLatch Latch Spacer 5 16 I D Washer 1 4 20 Kep Nut Feed Door Latch 7...

Страница 14: ...14 MODEL 1321 See Repair Parts List on Page 13 9 11 7 8 3 1 2 23 24 22 21 20 17 18 29 28 27 26 19 25 6 30 10 4 5 14 1 16 13 2 24 23 12 15 ...

Страница 15: ...ns Operation after loss of power 1 Remove filter if provided 2 Do not expect to keep home at normal temperatures 3 Do not load fuel above bottom of feed door 15 2 MIN AIR SPACE REQUIRED BY CODE 18 MIN CENTRAL FURNACE Fig 10 25 ...

Страница 16: ...6 PIPE DAMPER OPTIONAL 11 RPT 90 ELBOW FURNACE PIPE CONNECTOR Central Installation Fig 11 Add On Installation COLD AIR DUCT 6 PIPE DAMPER 90 ELBOW FURNACE PIPE CONNECTOR EXISTING GAS OIL ELECTRIC FURNACE 8 PIPE FIG 11 B ...

Страница 17: ...ed door and place paper and kindling on the grate for starting the fire 3 Light fire and close feed door 4 Add wood after fire is burning briskly Be careful not to smother the kindling fire 5 Set thermostat for desired temperature MEDIUM setting is normally satisfactory Set higher or lower for your comfort ADDING FUEL When starting a fire use small amounts of fuel This will allow for more complete...

Страница 18: ...point of the roof within 10 feet Fig 5 See page 19 for list of trouble shooting tips 5 6 A draft reading of 05 to 06 w c is suggested for proper burning of this unit when using wood Chimney Maintenance Creosote and Soot Formation and Need for Removal When wood is burned slowly it produces tar and other organic vapors which combine with expelled moisture to form creosote The creo sote vapors conden...

Страница 19: ... from furnace and duct work a Burning green wood not seasoned or dry b Thermostat setting too low for type fuel a Insufficient draft b Smothering fire when adding fresh fuel a Set thermostat higher b Clean chimney c Add raincap to chimney a Allow wood to season in a dry well ventilated area for 6 mo b Set blower control to higher temperatures c Set flue draft See page 9 a Wire unit properly b Repl...

Страница 20: ... 1321 FURNACE FILTER BOX APPENDIX INSTALLATION A NOTE INSTALL GRAVITY TYPE BACKDRAFT DAMPERS IN THE 8 ROUND HEAT OUTLET PIPES FOR SUPPLEMENTARY INSTALLS NOTE COMBINED STATIC PRESSURE IN OUTLET PLENUM MUST NOT EXCEED 0 25 INCHES WATER COLUMN WITH BOTH FURNACE S FANS RUNNING ...

Страница 21: ...D AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE MODEL 1321 FURNACE FILTER BOX PLENUM COLLECTOR BOX COLD AIR RETURN TO EXISTING DUCT WORK WARM AIR EXISTING FURNACE MODEL 1321 FURNACE FILTER BOX PLENUM ELBOW PLENUM TOP OPTIONAL ...

Страница 22: ...PLENUM FAN CONTROL LOCATION FURNACE PLENUM EXISTING FURNACE ANTI BACKDRAFT FLAPPER SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION D 2 MINIMUM CLEARANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION E BAFFLE ...

Страница 23: ...ANCE DUCT WORK FURNACE PLENUM EXISTING FURNACE SOLID FUEL FURNACE COLD AIR RETURN INSTALLATION F 2 MINIMUM CLEARANCE DUCT WORK SOLID FUEL FURNACE INSTALLATION G COLD AIR RETURN TO FILTER BOX CENTRAL FURNACE INSTALLATION ...

Страница 24: ...S ON THE NAMEPLATE ATTACHED TO THE FRONT OF THE FURNACE WHEN ORDERING REPAIR PARTS OR OPTIONS ALWAYS GIVE THE FOLLOWING INFORMATION AS SHOWN IN THIS LIST 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER 1321 4 The SERIAL NUMBER BEFORE INSTALLING YOUR HEATER FILL IN THE SERIAL NUMBER IN THE SPACE PROVIDED ABOVE FOR YOUR RECORDS UNITED STATES STOVE COMPANY 227 Industrial Park Rd P O Box 1...