background image

2

TABLE OF CONTENTS

IMPORTANT  SAFETY  INFORMATION ..................................................... .....3-4

PRODUCT   FEATURES..........................................................................................4

SPECIFICATIONS ............................................................................................... ....5

CONTENTS ............................................................................................................. 5

ITEMS  REQUIRED  FOR  INSTALLATION ........................................................ 6

INSTALLATION ...................................................................................................... 7

GAS  CONNECTION ........................................................................................... 8-9

GAS  PRESSURE  CHECK ..................................................................................... 9

LOG  ASSEMBLY ................................................................................................. 10

OPERATING  INSTRUCTIONS ...................................................................... 11-13

CLEANING / SERVICING ............................................................................... 13-14

FLAME   APPEARANCE ...................................................................................... 14

PARTS  LIST  FOR  HEATER  ASSEMBLY ................................................... 15-16

PARTS  LIST  FOR  BURNER &  LOG  ASSEMBLY......................................17-18

TROUBLE  SHOOTING .................................................................................. 19-20

OPTIONAL  EQUIPMENT.....................................................................................21

NOTE.......................................................................................................................22

LIMITED  WARRANTY  POLICY ....................................................................... 23

NOTICE

Installation and repair must be done by a qualified service person.  The appliance should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be
required due to excessive lint from carpeting, bedding material, etc.  It is imperative that control
compartments, burners and circulating air passageways of the appliance be kept clean.

Содержание Cavalier A9843L

Страница 1: ... phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET MANUFACTURED MOBILE HOME WHERE NOT PROHIBITED BY STATE OR LOCAL CODES Aftermarket Completion of sale not for purpose of resale from the ma...

Страница 2: ...SEMBLY 15 16 PARTS LIST FOR BURNER LOG ASSEMBLY 17 18 TROUBLE SHOOTING 19 20 OPTIONAL EQUIPMENT 21 NOTE 22 LIMITED WARRANTY POLICY 23 NOTICE Installationandrepairmustbedonebyaqualifiedserviceperson Theapplianceshouldbeinspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material etc It is imp...

Страница 3: ... by a qualified installer service agency or the gas supplier To prevent malfunction and or sooting an unvented gas heater should be cleaned at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting etc It is imperative that control compartments burners and circulating air passageways be kept clean Correct placement of the ceramic...

Страница 4: ... heater and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa Theheatermustbeisolatedfromthegassupplypipingsystembyclosingitsindividualmanualshutoffvalve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Do ...

Страница 5: ... position to light maintain a standing pilot 4 ON Gas flow to complete system front burner ignition Front Burner Control Knob Infinite control rotate clockwise to minimum rate and counter clockwise for maximum rate Rear Burner Control Knob Has 3 positions 1 OFF Gas to rear burner is shutoff at control 2 ON MAX Maximum gas flow to rear burner 3 MIN Minimum gas flow rate to rear burner GLOVESARERECO...

Страница 6: ...U per hour 4 8m per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space 3 ADEQUATE COMBUSTION AND VENTILATION AIR ITEMS REQUIRED FOR INSTALLATION ITEMS REQUIRED FOR INSTALLATION Ensure that the following ite...

Страница 7: ...ending the full width and depth of the appliance WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described in the National Fuel Gas Code ANSI Z223 1 Section 5 3 or applicable local codes L2 12 L1 15 1 2 W 12 H 8 Mini...

Страница 8: ...HEATER CONTROL VALVE STAINLESS FLEXIBLE TUBE PIPE COUPLING PIPE MANUAL SHUTOFF VALVE TEE JOINT PIPE NIPPLE CAP SEDIMENT TRAP Usenewblackironorsteelpipeonly Internallytinnedcoppertubingcanbeusedinsomeareas when permitted by local codes Only use pipe of 1 2 or greater diameter to allow full gas volume to heater Excessive pressure loss will occur if the pipe is too small A manual shutoff valve union ...

Страница 9: ...ring If the pressure is not as specified in Product Specifications Page 5 contact your dealer and replace the regulator FIGURE 6 Pressure Test Point Location Control Valve Control Bracket Rightside view facing heater Test Pressure Input Test Pressure Output Gas Inlet Connection 3 8 NPT FIGURE 5 Rear View of 9843 Vent Free Gas Heater The gas inlet connection is 3 8 NPT made at the rear of the main ...

Страница 10: ...t handle these logs with your bare hands Always wearglovestopreventskinirritationfromceramicfibers Afterhandlinglogs washyourhandsgentlywithsoapand water to remove any traces of fibers PROPER INSTALLATION SEQUENCE 1 Installtherearlog 2 ontherearsetoflocators Visuallychecktoverifythelogissecurelyplacedonthelocators 2 Install the front log 1 on the front locators Visually check to verify the log is ...

Страница 11: ... BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not attempt to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If ...

Страница 12: ...orandturnonelectricalpower OPERATING INSTRUCTIONS LIGHTING INSTRUCTIONS 1 Open access door 2 Set front burner to Min and turn off the rear burner by depressing knob and rotating clockwise until stop 3 Unplug all electric power optional blower if service is to be performed 4 Push in gas control knob slightly and turn clockwise to OFF Do not force 5 Close access door TURN OFF GAS TO APPLIANCE 1 STOP...

Страница 13: ...r you can light the pilot with a match First locate the pilot The pilot islocatedbetweenthetwoburnertubesontherightend facingtheunit insidethefirebox Tolightpilotwithamatch move the gas control knob 1 pg 12 to the pilot position and hold down Light match and place near pilot Once pilot is lit continue to hold the knob for about ten seconds Then follow steps 7 thru 10 on page 12 PILOT FLAME The pil...

Страница 14: ... Inspection Inspect and clean burner air intake holes Inspect and clean all burner ports Inspect ODS pilot for operation and accumulation of lint at air intake holes Verify flame pattern and log placement for proper operation FLAME APPEARANCE Verify smooth and responsive ignition of main burner and rear burner In normal operation at full rate after 15 minutes the following flame appearance should ...

Страница 15: ...15 HEATER ASSEMBLY REPLACEMENT PARTS 1 2 3 4 5 6 7 8 11 10 9 12 13 ...

Страница 16: ...EDESTAL WELDMENT 1 8 24599 PEDESTAL BASE 1 9 24457 CONTROL DOOR 1 10 89336 BRASS KNOB 1 11 83115 10 32 x 1 2 MACHINE SCREW 1 12 24614 FRONT SCREEN PAINTED 1 13 89869 BRASS TRIM 2 N S 89824 MAGNETIC LATCH 1 N S 83343 10 x 1 2 HX HD SCREWS 54 IMPORTANT NOTICE WHEN ORDERING CABINET PARTS PLACE THE APPROPRIATE CODE AFTER THE PART NUMBER THAT CORRESPONDS TO THE COLOR OF YOUR UNIT ALMOND A CHARCOAL GRAY...

Страница 17: ...17 BURNER LOG ASSEMBLY 5 16 15 6 8 9 2 3 7 4 10 11 17 1 19 18 A B C D 20 13 14 12 ...

Страница 18: ...ON SLEEVE 1 11 24612 PILOT BRACKET 1 12 89872 O P AMERICA NAT PILOT 1 89873 O P AMERICA L P PILOT 1 N S 83437 10 3 4 HX HD SCREW TO MOUNT PILOT 2 13 89841 3 16 COMPRESSION NUT 1 14 89842 3 16 COMPRESSION SLEEVE 1 15 89829 47 NATURAL BURNER ORIFICE FRONT 1 89836 55 L P BURNER ORIFICE FRONT 1 16 89830 48 NATURAL BURNER ORIFICE REAR 1 89836 55 L P BURNER ORIFICE REAR 1 17 24613 BURNER PAINTED 2 18 89...

Страница 19: ...lly clogged Open window and or door ventilation Contact local gas company Clean ODS Pilot Appliance shuts off in use Gas leak Control valve defective Locate and correct all leaks Replace control valve Gas odor even when control knob is in OFF position Gas supply turned off or manual shutoff valve closed Control knob not in PILOT position ControlknobnotpressedinwhileinPilot position Air in gas line...

Страница 20: ...ty or partially clogged burner orifice LP regulator shut down due to inlet pressure too high Hand tighten until snug then tighten 1 4 turn more Contact local gas company Replacethermocouple Replacecontrolvalve Clean burner or replace burner orifice Replace burner orifice Contact qualified service person Contact local gas company Clean burner or replace burner orifice Clean burner or replace burner...

Страница 21: ...T THIS OPTIONAL F40 BLOWER KIT IS AVAILABLE WHERE YOU PURCHASED THIS HEATER OR YOU CAN ORDER DIRECT FROM THE FACTORY BY CONTACTING THE PARTS DEPARTMENT AT THE NUMBER AND ADDRESS ON THE BACK PAGE OF THIS MANUAL BACK VIEW OF 9843 ...

Страница 22: ...22 NOTES ...

Страница 23: ...r MUST BE INSTALLED BY A QUALIFIED INSTALLER in accor dance with the instructions furnished with the unit The defective heater should be returned at your expense to the dealer from whom the product was purchased or an authorized service agent Any products presented for warranty repair must be accompanied by a dated proof of purchase Since some states do not allow the exclusion on limitation of inc...

Страница 24: ...UR RECORDS 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER 9843N 9843L 4 The SERIAL NUMBER THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE FURNACE AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE WHEN WRITING ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED INSIDE THE FRONT OF THE HEATER WHEN ORDERING...

Отзывы: