11
OPERATING
INSTRUCTIONS
‐
continued
the
Auger
feed
rate
will
help
keep
the
flames
from
extinguishing
on
the
minimum
heat
level
setting.
You
can
also
use
the
AUGER
TRIM
button
to
lower
heat
output
on
the
minimum
heat
level
setting:
Depress
and
release
the
AUGER
TRIM
button
until
the
heat
level
1
and
5
setting
lights
appear
to
slightly
increase
the
feed
rate
on
the
minimum
heat
level.
Depress
and
release
the
AUGER
TRIM
button
until
the
heat
level
1
and
4
setting
lights
appear
to
slightly
reduce
the
pellet
feed
rate
on
the
minimum
heat
level
setting.
Use
this
setting
to
reduce
the
heat
level
output
on
low.
Depress
and
release
the
AUGER
TRIM
button
until
only
the
heat
level
1
setting
light
is
on,
this
is
the
factory
setting
and
works
for
most
types
of
fuel.
Open
Door:
During
normal
operation
the
heater
will
automatically
shut
off
if
the
viewing
door
is
opened
for
more
than
30
seconds.
This
action
causes
the
heater
to
go
into
vacuum
error
mode.
To
clear
this
error
and
restart
the
heater,
close
the
door,
depress
the
ON/OFF
button
and
then
follow
directions
for
restarting
heater.
Refilling
the
Fuel
Hopper:
For
maximum
performance
do
not
let
the
pellet
fuel
hopper
drop
below
1/4
full.
Fuel
Hopper
Lid
Safety
Switch:
When
the
Fuel
Hopper
Lid
is
opened
the
auger
will
stop
turning
to
prevent
accidental
injury.
KEEP
PELLET
FUEL
HOPPER
LID
CLOSED
AT
ALL
TIMES
EXCEPT
WHEN
REFILLING.
DO
NOT
OVERFILL
HOPPER.
Safety
Features
and
warning
code:
1.
Your
heater
is
equipped
with
a
temperature
“high
‐
limit”
switch,
designed
to
shutdown
the
auger
in
case
of
an
over
temperature
situation.
The
high
‐
limit
switch
is
a
thermo
snap
disc
type
and
must
be
manually
reset
in
the
event
of
an
overheat
shutdown.
Once
the
heater
has
cooled
down,
you
can
reactivate
the
high
‐
limit
switch
by
depressing
the
manual
reset
button
located
on
the
high
‐
limit
switch.
2.
When
the
High
‐
Limit
switch
opens,
which
indicates
an
overheat
failure,
the
HEAT
LEVEL
LED’s
3
&
4
will
flash
red.
3.
Your
heater
is
equipped
with
a
vacuum
switch
that
automatically
shuts
down
the
auger
in
the
event
of
a
exhaust
fan
malfunction.
4.
When
a
Vacuum
Error
is
sensed,
the
HEAT
LEVEL
LED’s
1
&
2
will
flash
red.
Check
to
ensure
the
glass
door
is
latched
properly.
5.
When
the
Low
‐
Limit
switch
opens,
(fire
went
out)
the
HEAT
LEVEL
LED’s
4
&
5
will
flash
red.
First
check
fuel
supply,
then
check
to
ensure
Auger
is
not
jammed
and
finally
that
pellet
hopper
door
is
properly
closed.
6.
When
the
Pellets
in
the
Burn
Pot
fail
to
ignite
HEAT
LEVEL
LED’s
1
&
5
will
flash
red.
NOTE:
In
the
event
that
the
high
‐
limit
switch
or
vacuum
switch
activates,
please
contact
your
dealer
to
discuss
the
cause
of
this
activation
and
to
ensure
that
your
heater
continues
to
operate
in
a
safe
manner.
Either
switch
tripping
can
indicate
a
problem
with
the
operation
of
your
heater.