26
MAINTENANCE
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED MAY RESULT IN POOR PERFORMANCE
AND HAZARDOUS SITUATIONS. CLEAN THE HEATER FREQUENTLY AS ACCUMULATION OF SOOT,
CREOSOTE OR FLYASH MAY OCCUR. NEVER CLEAN THE UNIT WHEN HOT.
Burn Pot:
Note: Let the unit cool to room temperature before inspecting the burn pot. Inspect the burn pot regularly to check
that the holes have not become plugged. If necessary clean thoroughly. It is imperative that the burn pot be re-
installed the correct way or the unit will not light. The end of the burn pot with an igniter hole in it (see Figure 23)
must be installed facing the rear of the unit. This hole allows the igniter to heat up the pellets to the point of ignition.
Figure 23
Figure 23
Igniter Hole
Burn Pot Removed
Ash Pan Door
Содержание 5660 (I)
Страница 25: ...25 VENT TERMINATION LOCATIONS Figure 22 ...