USR-W630 User Manual
Technical Support:
Jinan USR IOT Technology Limited
www.usriot.com
24
Figure 22 socket function
This function is deactivated by default.
4.13. Timeout Restart Function
If the W630 is disconnected or W630 is connected but not communicating, it will restarted within the set time when
the timeout function is turned on. The timeout time can be set to 60-65535s and the default time is 3600s. The restart
conditions are as follows:
(1) When WIFI is disconnected, the timing unit will start and the connection will be cleared. If the timing unit exceeds
the time of overtime restart, the W630 will be restarted.
(2) WIFI connection is established and no communication also starts timing, if there is communication, the clear
timing unit, if the timing time exceeds the timeout restart time, then restart the W630.
This function defaults by default.