Device information
Disable/IMEI/SN/MAC/ICCID
Disable
Event
13 event status
Uncheck
Description:
1. DO control cannot be used simultaneously with DO function in DI/DO. If only enable DO1 in DI/DO,
please select DO2 here.
2. SMS supports up to 140 bytes, including the description, event, time and the message. Do not make the
description too long to avoid receiving incomplete messages.
3. Please ensure the device has connected to the 4G network and the SIM card supports SMS function
before sending SMS.
4. Please ensure the device has connected to the network before sending email.
5. DO alarm is triggered continuously until the next DO is triggered.
6. WAN-4G online: Alarm after successful 4G networking.
7. WAN-4G offline: Alarm after connecting to the 4G network again.
8. Network type change: Alarm when changing the network.
9. WAN up: Alarm when connecting to wired network.
10. WAN down: Alarm when the wired network disconnect.
11. System reboot: Alarm if the device restart without power off.
12. DI 1 ON: Valid when DI1 mode is ON-OFF in “DIDO”, alarm when DI1 is triggered.
13. DI 1 OFF: Valid when DI1 mode is ON-OFF in “DIDO”, alarm when DI1 trigger is canceled.
14. DI1 counter overflow: Valid when DI1 mode is Counter in “DIDO”, alarm when DI1 reaches the threshold
value.
15. DI 2 ON: Valid when DI2 mode is ON-OFF in “DIDO”, alarm when DI2 is triggered.
16. DI 2 OFF: Valid when DI2 mode is ON-OFF in “DIDO”, alarm when DI2 trigger is canceled.
17. DI2 counter overflow: Valid when DI2 mode is Counter in “DIDO”, alarm when DI2 reaches the threshold
value.
18. Cellular data traffic overflow: This function needs the device to be added in USR Cloud, and enable
“Data traffic control” in “Cellular Network”.
9.6. Alert Examples
9.6.1.Flow Consumption Alarm via Email
1. Add the device in USR Cloud, please refer to