USR-G761w Guide Line
h.usriot.com
Jinan USR IOT Technology Limited
www.usriot.com
21
/
35
Example: AT+ UARTFL =1000
8.1.2.20.
AT+RFCEN
Function: Query/Set whether enable Automatic Baud Rate Synchronization
Format:
Query current parameters:
AT+RFCEN{CR} or AT+RFCEN?{CR}
{CR}{LF}+RFCEN: status{CR}{LF}{CR}{LF}OK{CR}{LF}
Set:
AT+RFCEN=status{CR}
{CR}{LF}OK{CR}{LF}
Parameters:
Status: enable status of Automatic Baud Rate Synchronization, including:
ON: enable
OFF: disable
Example: AT+RFCEN=ON
8.1.2.21.
AT+APN
Function: Query/Set APN
Format:
Query current parameters:
AT+APN{CR} or AT+APN?{CR}
{CR}{LF}+APN: code, username, password{CR}{LF}{CR}{LF}OK{CR}{LF}
Set:
AT+APN=code, username, password{CR}
{CR}{LF}OK{CR}{LF}
Parameters:
Code: APN
username: user name
password: password
example: AT+APN=3gnet
8.1.2.22.
AT+SOCKA
Function: Query/Set parameters of socket A
Format:
Query current parameters:
AT+SOCKA{CR} or AT+SOCKA?{CR}
{CR}{LF}+SOCKA: protocol, address, port{CR}{LF}{CR}{LF}OK{CR}{LF}
Set:
AT+SOCKA=protocol, address, port{CR}