USR-G761w Guide Line
h.usriot.com
Jinan USR IOT Technology Limited
www.usriot.com
18
/
35
Format:
Query current parameters
AT+CSQ{CR} or AT+CSQ?{CR}
{CR}{LF}+CSQ:RSSI,BER {CR}{LF}{CR}{LF}OK{CR}{LF}
Parameters:
RSSI: received signal strength indicator
0, equal to or less than -125 dBm
1~30, round numbers (31×
(
125
-
|rssi|
)
/ 50) dBm
31, equal to or greater than -75 dBm
99, unknown or unpredictable
BER:
(
bit error rate percentage
)
: Doesn’t support BER query at present, will respond 99 in execution
command and test command.
8.1.2.10.
AT+RELD
Function: reload to user default setting, USR-G761w will restart
Format:
Execute specified function:
AT+RELD{CR}
{CR}{LF}OK{CR}{LF}
8.1.2.11.
AT+CLEAR
Function: reload to factory defaults, USR-G761w will restart.
Format:
Execute specified function:
AT+CLEAR{CR}
{CR}{LF}OK{CR}{LF}
8.1.2.12.
AT+CFGTF
Function: Save current settings to be user-default setting.
Format:
Execute specified function:
AT+CFGTF{CR}
{CR}{LF}OK{CR}{LF}
8.1.2.13.
AT+VER
Function: Query firmware version
Format:
Query current parameters: