background image

Page 9

THIS PRODUCT IS LISTED TO CAN/ULC S531-02 STANDARD FOR SMOKE ALARMS

BY UNDERWRITERS LABORATORIES, INC.

Blinks On once

approx every

40-45 seconds

Stays On

Condition: 

AC Power is present. DC Power is present.

Recommendation:

 None, alarm is operating properly.

Blinks On once 

approx every

40-45 seconds

Off

Condition:

 AC Power is not present and alarm is receiving DC Power.

Recommendation:

  Check  the  breaker  or  fuse  box  for  power.  If 

the breaker or fuse box looks normal, call a licensed electrician for 

assistance.

OPERATIONAL SUMMARY

Silent

Silent

Blinks On

approx every

2 seconds

Stays On

Condition:

 Nuisance Alarm.

Recommendation:

 If there is no hazard present, verify the alarm is 

mounted in the correct location (see User's Manual, "AVOID THESE 

LOCATIONS" section). Reset alarm as instructed below.

Horn does not 

sound when other 

alarms are active 

or horn does not 

sound when

interconnected 

alarms test

Blinks On once

approx every

40-45 seconds

Stays On

or Off

Condition:

 One or more alarms not responding to interconnected alarm.

Recommendation:

 Press and hold the smoke alarm Test/Silence 

button for at least 5 seconds. If still no alarm, turn off AC Power at the 

circuit breaker or fuse box and disconnect the alarm from the mounting 

bracket and make sure the connector plug is securely attached on units 

that did not alarm. If still no alarm, have a licensed electrician check 

to see the yellow wire is not mistakenly or accidentally connected to 

the white (neutral) wire.

3 Beeps,

2 second pause,

Repeat

Blinks On

approx every

2 seconds

Stays On

Condition:

 Originating Smoke Alarm.

Recommendation:

 If hazard is identified, please take all precautions 

if an alarm sounds by calling an Emergency Service and getting 

out of the home.

3 Beeps,

2 second pause,

Repeat

Off

Stays On

Condition:

 Non-originating Smoke Alarm.  Another interconnected 

smoke alarm has sensed smoke, causing all interconnected units 

to alarm.

Recommendation:

 If hazard is identified, please take all precautions 

if an alarm sounds by calling an Emergency Service and getting 

out of the home.

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks On 

once approx every

10 seconds

(silence mode)

Stays On

Condition:

 One alarm has sensed smoke.

Recommendation:

 QUICK FIND

®

 Alarm Origination - In an 

interconnected system, it is difficult to determine which alarm initiated 

the alarms to sound. The QUICK FIND

®

  feature  will  immediately 

allow  you  to  locate  the  originating  alarm  (once  the  alarms  have 

stopped sounding). To initiate QUICK FIND

®

, press the Test/Silence 

button on any alarm. After releasing the button, the test sequence 

will sound and then stop. Then, the originating alarm will continue to 

sound for approx 50 seconds. In a non-interconnected installation, it 

is necessary to test each alarm to determine the originating alarm. 

Reset the originating alarm.

Blinks On once

approx every

40-45 seconds

Stays On

Condition:

 Alarm needs to be reset due to varying conditions/

previous alarms.

Recommendation:

 To Reset the Alarm, hold the Test/Silence button 

for approx 10 seconds. This will clear alarm origination. Reset after 

each smoke alarm event.

Silent

1 Chirp

approx every

40 seconds

Stays On

Condition:

 Low Battery

Recommendation: 

Check to make sure the battery activation pull 

tab has been completely removed, battery polarity is correct and the 

battery terminals are making contact with the smoke alarm contacts 

in the battery drawer. If chirp continues, replace the 9V battery (see 

User's Manual for recommended battery types).

3 Beeps,

2 second pause,

Repeat

3 Beeps,

2 second pause,

Repeat

Stays On

Condition:

 Alarm has sensed smoke.

Recommendation:

 Silence Feature is activated by pressing and 

releasing the Test/Silence button on the initiating alarm while in alarm 

condition. Silence mode will last for approx 8-12 minutes with the red 

LED blinking once approx. every 10 seconds.

Blinks On

approx every

2 seconds

Silent

(alarmed

previously)

CONDITION /  RECOMMENDATION

HORN

RED LED

GREEN LED

Blinks On once

approx every

40-45 seconds

(normal operation

mode) or Blinks On 

once approx every

10 seconds

(silence mode)

Содержание UNIVERSAL 2995CN

Страница 1: ...urself Table of Contents Page Smoke Alarm Limitations and Functions 2 Recommended Location of Alarms 3 Avoid These Locations 4 Early Warning 4 Installation Instructions 4 Electrical Shock Hazard 4 Loc...

Страница 2: ...LOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD l INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSU...

Страница 3: ...r than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Sm...

Страница 4: ...all at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall not be located where airflow prevents smoke fr...

Страница 5: ...5CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7...

Страница 6: ...andard household wire 18 gauge or larger rated at least 300V as required by local codes available at all electrical supply hardware stores The wiring to be used shall be in accordance with the provisi...

Страница 7: ...will not normally set off the alarm unless smoke is blown directly into the smoke alarm Combustion particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooki...

Страница 8: ...CTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room Second story windows may need a rope or chain ladder o H...

Страница 9: ...ied please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home Blinks On once approx every 40 45 seconds normal operation mode or Blinks On once approx...

Страница 10: ...T AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE L...

Отзывы: