RECOMMENDED LOCATION OF ALARMS

•  Locate the first smoke alarm in the immediate area of the bedrooms. Try to protect the escape 

route as the bedrooms are usually farthest from an exit. If more than one sleeping area exists, 

locate additional smoke alarms in each sleeping area. If a hall is more than 40 feet (12 meters) 

long, install a smoke alarm at each end.

•  Locate additional smoke alarms to protect any stairway as stairways act like chimneys for smoke 

and heat.

•  Locate at least one smoke alarm on every floor level.

•  Locate a smoke alarm in any area where a smoker sleeps or where electrical appliances are 

operated in sleeping areas.

•  Smoke, heat and other combustion products rise to the ceiling and spread horizontally. Mounting 

the smoke alarm on the ceiling in the center of the room places it closest to all points in the room. 

Ceiling mounting is preferred in ordinary residential construction. However, in mobile homes, 

wall mounting on an inside partition is preferred to avoid the thermal barrier that may form at the 

ceiling.

•  When mounting smoke alarm on a wall, if local codes allow, use an inside wall with the top  

edge of the smoke alarm a maximum of 12" (30.5cm) below the ceiling/wall intersections (See 

Diagram A).

Page 3

Sloped Ceilings (Peaked Ceilings):

Smoke alarms or smoke detectors mounted on a peaked ceiling shall be located within 36 in. (914 mm) 

horizontally of the peak, but not closer than 4 in. (102 mm) vertically to the peak.
Sloped Ceilings (Shed Ceilings):

Smoke alarms or smoke detectors mounted on a sloped ceiling having a rise greater than 1 ft. in 8 ft. (1 

m in 8 m) horizontally shall be located within 36 in. (914 mm) of the high side of the ceiling, but not closer 

than 4 in. (102 mm) from the adjoining wall surface.
Tray-Shaped Ceilings:

Smoke Alarms or smoke detectors shall be installed on the highest portion of the ceiling or on the sloped 

portion of the ceiling within 12 in. (305 mm) vertically down from the highest point.
Mobile Home Installation:

For minimum protection, smoke alarms  should be installed in compliance with H.U.D. Manufactured 

Home Construction Safety Standards, Title 24 CFR, Section 3280.208 and Section 3282. For additional 

protection, see Single Story Residence smoke alarm requirements/recommendations for Existing Homes 

and New Construction Homes.
Note: For mobile homes built before 1978, install smoke alarms on inside walls between 4” and 12” from 

the ceiling (older mobile homes have little or no insulation in the ceiling). This is especially important if 

the ceiling is unusually hot or cold.
Install a smoke alarm inside each bedroom and in the hallway outside each separate sleeping area.

Existing Homes:

The NFPA requires a smoke alarm on every level and outside each sleeping area in existing construction. 

An existing household with one level and one sleeping area is required to have one smoke alarm.
New Construction Homes and Manufactured Homes:

The NFPA requires AC-powered, interconnected smoke alarms to be installed inside each bedroom, outside 

each bedroom area, and on every level of the home. They also require a minimum of two AC-powered, 

interconnected smoke alarms in any new construction home.

Ceiling

Acceptable

Top of detector

acceptable here

Sidewall

12 in.

(300 mm)

maximum

Note: Measurements shown are to 

the closest edge of the detector.

DIAGRAM A 

Содержание UNIVERSAL 2995CN

Страница 1: ...urself Table of Contents Page Smoke Alarm Limitations and Functions 2 Recommended Location of Alarms 3 Avoid These Locations 4 Early Warning 4 Installation Instructions 4 Electrical Shock Hazard 4 Loc...

Страница 2: ...LOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR ARSON FIRE PREVENTION IS YOUR BEST SAFEGUARD l INSTALLING SMOKE ALARMS MAY MAKE YOU ELIGIBLE FOR LOWER INSU...

Страница 3: ...r than 1 ft in 8 ft 1 m in 8 m horizontally shall be located within 36 in 914 mm of the high side of the ceiling but not closer than 4 in 102 mm from the adjoining wall surface Tray Shaped Ceilings Sm...

Страница 4: ...all at least 3 feet 0 9 meters away from these areas in areas of turbulent air such as air returns or heating and cooling supply vents smoke alarms shall not be located where airflow prevents smoke fr...

Страница 5: ...5CN therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnected system The following alarms cannot reset units on an interconnected system USI 7...

Страница 6: ...andard household wire 18 gauge or larger rated at least 300V as required by local codes available at all electrical supply hardware stores The wiring to be used shall be in accordance with the provisi...

Страница 7: ...will not normally set off the alarm unless smoke is blown directly into the smoke alarm Combustion particles from cooking may set off the alarm if the smoke alarm is located close to the kitchen cooki...

Страница 8: ...CTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room Second story windows may need a rope or chain ladder o H...

Страница 9: ...ied please take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home Blinks On once approx every 40 45 seconds normal operation mode or Blinks On once approx...

Страница 10: ...T AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED BY STATE L...

Отзывы: