Silent

Off

OPERATIONAL SUMMARY

RECOMMENDATION

HORN

RED LED

GREEN LED

New - Out of Package

To activate the alarm, remove the pull tab. The 

alarm will sound one long beep to confirm it is 

powered up. Press the Test/Silence/Reset/Peak 

button. Test the alarm following installation and 

weekly thereafter. The built-in test switch accurately 

tests the alarm operation as required by ANSI/

UL217 Standards for Safety Standards for Safety. 

If, at any time, you test the alarm and it does not 

perform as described, replace it immediately.

CONDITION

RECOMMENDATION

Off

Blinks On once

approx every

2 minutes

AC Power is present

DC Power is present

ALARM AUDIBLE & VISUAL SIGNALS

Silent

Stays On

Alarm is operating properly.

Blinks On once

approx every

2 minutes

AC Power is not present

DC Power is present

Silent

Off

Check the breaker or fuse box for power. If the 

breaker or fuse box looks normal, call a licensed 

electrician for assistance.

Blinks On

 in sync

with horn

3 Beeps,

2 second pause,

Repeat

Press and hold the smoke alarm Test/Silence 

button for at least 5 seconds. If still no alarm, 

turn off AC Power at the circuit breaker or 

fuse box and disconnect the alarm from the 

mounting bracket and make sure the connector 

plug is securely attached on units that did not 

alarm. If still no alarm, have licensed electrician 

make sure the yellow wire is not mistakenly or 

accidentally connected to the white (neutral) 

wire. NOTE: In an interconnected system 

containing a CO alarm, the CO alarm will 

not respond to the smoke alarm signal and 

the smoke alarm will not respond to the CO 

alarm signal.

Blinks On once

approx every

2 minutes

One or more alarms 

not responding to 

interconnected alarm

Horn does not

sound when other 

alarms are active

or horn does 

not sound when 

interconnected 

alarms test button

is pressed

Stays On

Originating Smoke Alarm

Stays On

If alarm sounds and hazard is identified, 

please take all precautions by getting out of 

the home immediately and then calling an 

Emergency Service. 

Non-originating 

smoke alarm. Another 

interconneced smoke

alarm has sensed smoke, 

causing all interconnected 

units to alarm. 

3 Beeps,

2 second pause,

Repeat

Off

Stays On

If alarm sounds and hazard is identified, 

please take all precautions by getting out of 

the home immediately and then calling an 

Emergency Service. 

Nuisance Alarm

3 Beeps,

2 second pause,

Repeat

Blinks On in

sync with horn

Stays On

If there is no hazard present and the unit is 

still sounding, activate the silence feature by 

pressing and releasing the Test/Silence button 

on the initiating alarm. Silence mode will last 

for approx 8-12 minutes, with the red LED 

blinking once approx every 10 seconds. Verify 

the alarm is mounted in the correct location (see 

User's Manual, "AVOID THESE LOCATIONS" 

section). Reset alarm as instructed below.

One alarm has sensed 

smoke and is

now silent.

Silent

Blinks On once 

approx every

2 minutes

(normal

operation mode)

or Blinks On

once approx

 every 10 seconds

(silence mode)

Stays On

QUICK FIND

®

 Alarm Origination - In an 

interconnected system, it is difficult to determine 

which alarm initiated the alarms to sound. The 

QUICK FIND

®

 feature will immediately allow 

you to locate the originating alarm (once the 

alarms have stopped sounding). To initiate 

QUICK FIND

®

, press and release the Test/

Silence button on any alarm.  After releasing 

the button, the test sequence will sound and 

then stop. Then the originating alarm will 

continue to sound for approx 60 seconds. In a 

non-interconnected installation, it is necessary 

to test each alarm to determine the originating 

alarm. Reset alarm as instructed below.

Alarm needs to be reset

due to varying

conditions/previous

alarms

Stays On

Silent

To   R e s e t   t h e  A l a r m ,   p r e s s   t h e  

Test/Silence button for approx 10 seconds. This 

will clear Alarm Origination. Reset after each 

smoke alarm event.

Blinks On once 

approx every

2 minutes

(normal operation 

mode)

or Blinks On

once approx

 every 10 seconds

(silence mode)

Test the alarm following installation and 

weekly thereafter. The built-in test switch ac-

curately tests the alarm operation as required 

by ANSI/UL217 and UL2034 Standards for 

Safety. If, at any time, the alarm does not 

perform as de scribed during the test, replace 

it immediately.

The Test button has been 

pressed. The test sequence 

lasts for approx 10 seconds.

3 Beeps, 2 second 

pause.

Blinks On in sync 

with 3 beeps.

Blinks On in 

sync with 4 

beeps.

OPERATIONAL SUMMARY (continued on page 11)

THIS PRODUCT CONFORMS TO UL 217 STANDARD FOR SAFETY

BY UNDERWRITERS LABORATORIES, INC.

Содержание MP116S

Страница 1: ...operate maintenance testing and product features It also includes tips and information which could help protect you and your family Table of Contents Page Smoke Alarm Limitations and Functions 2 Reco...

Страница 2: ...nd properties SMOKE ALARMS CANNOT DETECT FIRES IF THE SMOKE DOES NOT REACH THEM Smoke from fires may not reach the sensing chamber and set off the alarm One alarm should be installed inside each bedro...

Страница 3: ...Title 24 CFR Section 3280 208 and Section 3282 For additional protection see Single Story Residence smoke alarm requirements recommendations for Existing Homes and New Construction Homes Note For mob...

Страница 4: ...et Page 4 Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate slee...

Страница 5: ...terconnected system USI 7795 The following alarms can trigger Quick Find Alarm Origination but will not indicate Alarm Origination on an interconnected system USI 1103 USI 1203 USI 1204 USI 1208 Part...

Страница 6: ...reen LED should be on to indicate AC power The red LED blinks on once approx every 2 minutes to indicate proper operation 120 VAC 60Hz 100mA Max OPERATION TESTING MAINTENANCE NORMAL OPERATION The alar...

Страница 7: ...arm origination and to return your system to normal operation Refer to the wiring instructions model interconnect compatibility section of this manual Page 5 for additional information In a non interc...

Страница 8: ...alarm DO NOT disassemble or attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or grease and cannot be cleaned it should be...

Страница 9: ...and at least two escape routes from each room Second story windows may need a rope or chain ladder o Have a family meeting and discuss your escape plan showing everyone what to do in case of fire o D...

Страница 10: ...On If alarm sounds and hazard is identified please take all precautions by getting out of the home immediately and then calling an Emergency Service Nuisance Alarm 3 Beeps 2 second pause Repeat Blinks...

Страница 11: ...consequential or incidental loss or damage including but not limited to damages to any equipment with which this product is used Some states do not allow the exclusion or limitation of incidental or...

Отзывы: