NATIONAL FIRE PROTECTION ASSOCIATION REQUIRED INFORMATION

For your information, the National Fire Alarm Code, NFPA 72, reads as follows:
"11.5.1 *Required Detection - Where required by applicable laws, codes, or standards for a specific
type of occupancy, approved single and multiple-station smoke alarms shall be installed as follows:
(1) *In all sleeping rooms and guest rooms
(2) *Outside of each separate dwelling unit sleeping area, within 6.4 m (21 ft) of any door to a
sleeping room, the distance measured along a path of travel
(3) On every level of a dwelling unit, including basements.
(4) On every level of a residential board and care occupancy (small facility), including basements
and excluding crawl spaces and unfinished attics
(5) *In the living area(s) of a guest suite
(6) In the living area(s) of a residential board and care occupancy"

The equipment should be installed using wiring methods in accordance with the

National Fire Protection Association's Standard 72.

(National Fire Protection Association, Batterymarch Park, Quincy, MA 02269)

Содержание MDSCN103 IoPhic

Страница 1: ...otect you and your family PLEASE READ AND SAVE Table of Contents Page Alarm Limitations and Functions 2 What You Should Know About CO 3 What You Should Know About Natural Gas 3 Basic Safety Informatio...

Страница 2: ...ETY HAZARDS LIKE SMOKING IN BED VIOLENT EXPLOSIONS ESCAPING GAS IMPROPER STORAGE OF FLAMMABLE MATERIALS OVERLOADED ELECTRICAL CIRCUITS CHILDREN PLAYING WITH MATCHES NATURAL CAUSES SUCH AS LIGHTNING OR...

Страница 3: ...ES This product is intended for use in ordinary indoor locations of family living units It is not designed to measure compliance with Occupational Safety and HealthAdministration OSHA commercial or in...

Страница 4: ...one sleeping area exists locate additional combination alarms in each sleeping area If a hall is more than 40 feet 12 meters long install a combination alarm at each end Locate additional alarms to p...

Страница 5: ...ay harm your hearing Make sure the alarm is not receiving excessively noisy power Examples of noisy power could be major appliances on the same circuit power from a generator or solar power light dimm...

Страница 6: ...et 6m from the sources or combustion particles stove furnace water heater space heater if possible In areas where a 20 foot 6m distance is not possible in modular mobile or smaller homes for example i...

Страница 7: ...ailure to connect this alarm to a 24 hour circuit may prevent it from providing constant protection IMPORTANT Do not subject this alarm to megger high voltage or high pot tests Remove the alarm s befo...

Страница 8: ...models MDSCN111 MSDCN103 MICN109 MICN102 MCN108 and MCN105 therefore a natural gas alarm will NOT trigger the alarm of non natural gas sensing models within an interconnected system The following alar...

Страница 9: ...time depends on the strength freshness of the battery The battery backup will not work unless a good battery is properly installed When the alarm utilizes battery backup power the natural gas sensor w...

Страница 10: ...Periodically the alarm measurement circuit is tested If an error is detected the alarm will sound 3 chirps approx every 20 seconds Reset the alarm If the unit does not reset replace the alarm END OF...

Страница 11: ...dangerous situation and the horn will sound again Ventilate area Page 11 Some individuals are more sensitive to CO than others including people with cardiac or respiratory problems infants unborn bab...

Страница 12: ...check for the presence of CO or gas WARNING Natural gas methane is highly explosive An attempt to test the unit by exposing it to natural gas outside of a controlled labatory environment can produce...

Страница 13: ...nt in other areas without reaching the alarm CO or gas could be present on one level of the home and not reach the alarm installed on a different level For example CO or gas in the basement may not re...

Страница 14: ...nsumer is exempt from any licensing or requirements Simultaneous operation of several fuel burning appliances competing for limited internal air Vent pipe connections vibrating loose from clothes drye...

Страница 15: ...sleeping area within 6 4 m 21 ft of any door to a sleeping room the distance measured along a path of travel 3 On every level of a dwelling unit including basements 4 On every level of a residential...

Страница 16: ...tedGASalarmhassensed GAS causing all interconnected units to sound If hazard is identified take all precautions if an alarm sounds by calling an Emergency Service and getting out of the home 3 Beeps 2...

Страница 17: ...2 Chirps approx every 20 seconds Off Off Condition Product End of Service Life Notification Recommendation Replace the alarm immediately The product end of service life notification can be temporaril...

Страница 18: ...OT WARRANT AND SPECIFICALLY DISCLAIMS ANY WARRANTY WHETHER EXPRESS OR IMPLIED OF FITNESS FOR A PARTICULAR PURPOSE OTHER THAN THE WARRANTY CONTAINED HEREIN NO IMPLIED WARRANTY ON THIS PRODUCT CREATED B...