background image

 

Fl Protect Set 

Hot water Shut-off valve 

for the Fl System 

Operating Manual 

 

 

 
 

Содержание FlowTimer+ Protect Set

Страница 1: ...FlowTimer Protect Set Hot water Shut off valve for the FlowTimer System Operating Manual...

Страница 2: ...Printing date 04 03 2019 Copyright usetech GmbH This documentation including all its parts is protected by copyright Any use or modification outside the narrow limits of copyright law without the cons...

Страница 3: ...afety instructions 8 5 System description FlowTimer Protect Set 9 5 1 Content of the FlowTimer Protect Set 9 5 2 FlowTimer Protect front view 10 5 3 FlowTimer Protect rear view 11 6 Installation 12 6...

Страница 4: ...pass operation 19 8 2 Status display 20 9 Troubleshooting Maintenance 21 9 1 No display 21 9 2 Alarm signals 22 9 2 1 Status display permanently red 22 9 3 Maintenance 23 10 Shutting down 24 11 Packag...

Страница 5: ...Non observance of these instructions can lead to dangerous situations The operating instructions must be read and understood 1 1 Explanation of symbols DANGER Warns of imminent danger Failure to do so...

Страница 6: ...at are important for your safety and the proper functioning of the system refers to information in this operating manual or other documentation Action steps The defined sequence of steps makes it easi...

Страница 7: ...h IT standard version 2 3 Environmental and climate conditions Ambient temperature 5 C 40 C Media temperature drinking water 5 80 C Protection class IP20 Location only suitable for indoor use 2 4 Life...

Страница 8: ...on our part is void as is the warranty on the system and accessories There are drinking water heating systems in which heated water runs after the cold water supply has been shut off The FlowTimer Pro...

Страница 9: ...rinking water The system is not suitable for rainwater other liquids or gases The FlowTimer Protect may only be used with the components in the set or other FlowTimer products unless explicitly stated...

Страница 10: ...ife threatening The installation of a stationary power supply must be carried out by a qualified electrician The system must be commissioned and if necessary adapted by a specialist The local conditio...

Страница 11: ...03 19 FlowTimer Protect Set 9 5 System description FlowTimer Protect Set 5 1 Content of the FlowTimer Protect Set Fig 5 1 Content of the FlowTimer Protect Set 1 Plug in power supply 2 3 4 inch Shut of...

Страница 12: ...System description FlowTimer Protect Set 03 19 FlowTimer Protect Set 10 5 2 FlowTimer Protect front view Fig 5 2 FlowTimer Protect front view 5 Device illuminated rim Status display...

Страница 13: ...t 03 19 FlowTimer Protect Set 11 5 3 FlowTimer Protect rear view Fig 5 3 FlowTimer Protect rear view 14 I O connection 15 Solenoid 16 Year of construction Serial number 17 Pressure sensor connection n...

Страница 14: ...essure reducer must be installed upstream of the FlowTimer Protect If no filter has been installed in the cold water inlet of the entire system it should now be retrofitted to protect the valve from c...

Страница 15: ...open for maintenance work The Allen screws on the valve upper body must be accessible from the outside The selected mounting position must allow the assembly and disassembly of the control electronics...

Страница 16: ...d on the armature tube of the valve 4 Then press briefly and forcefully on top of the solenoid coil not on the electronics until the coil audibly engages in the holder Thus the coil is mounted correct...

Страница 17: ...wTimer Hub to the I O port 14 of the FlowTimer Protect using the I O connection cable Plug the power supply unit into a suitable socket and connect the power supply unit to the power supply connection...

Страница 18: ...Air in the hot water supply e g in the hot water storage tank can lead to scalding due to hot water running in if the water supply is interrupted Disconnect the power supply of the FlowTimer Protect...

Страница 19: ...lay of the FlowTimer FlowTimer Hub and FlowTimer Protect must now be permanently red At the moment of the interruption of the cold water section it must no longer be possible to detect that the hot wa...

Страница 20: ...f a solenoid diaphragm valve The FlowTimer Protect operating status can be seen via the illuminated bezel 5 see chapter8 2 Status display An operation of FlowTimer Protect is not necessary because an...

Страница 21: ...utlet or disconnect the power supply In order to ensure a water supply during a power failure or troubleshooting the system can be deactivated for this period of time The protective function is then n...

Страница 22: ...ere s no alarm pending Yellow flashes The valve is moved briefly to prevent calcification The hot water supply was automatically interrupted by FlowTimer Protect Red duration An alarm or cable break h...

Страница 23: ...r given 9 1 No display If the FlowTimer Protect does not display a status make sure that the power supply is working and that the power supply is plugged in If there is still no display the system mus...

Страница 24: ...ay of the FlowTimer Hub and the connected individual FlowTimer as well as the connection cable between Hub and Protect please use the instructions of the respective products The I O connection cable i...

Страница 25: ...f automatically Recommissioning after prolonged standstill After a longer standstill an inspection must be carried out by a specialist interval plot Weekly Visual inspection of the status display see...

Страница 26: ...f the FlowTimer system is not to be used for a longer period of time Pull out power supply unit Recommissioning When the unit is put back into operation it must be inspected by a specialist The FlowTi...

Страница 27: ...moisture and dirt and transport it in shockproof packaging Avoid exceeding or falling below the permissible storage temperature Protect electrical connections from damage with protective caps The syst...

Страница 28: ...ent Act ElektroG Please dispose of old equipment at a municipal collection point as required by law or hand it over to your local dealer free of charge Disposal with household waste is expressly forbi...

Страница 29: ...e use of certain hazardous substances in electrical and electronic equipment The usetech GmbH Tanzplatz 10 D 55130 Mainz declares that Product Name Flowtimer Protect Type V1 2 Year of construction 201...

Страница 30: ...Declaration of Conformity Valve 03 19 FlowTimer Protect Set 28 14 Declaration of Conformity Valve...

Отзывы: