INSTALLATION (continued) 

ELECTRICAL INSTALLATION 

1. Refer to the nameplate.  Verify the electrical

service power.  Voltage and phase must

match the nameplate specifications.

Wiring the unit to the wrong voltage can

severely damage the unit or cause noticeably

decreased performance.

2. Available electrical service amperage must

meet or exceed the specifications listed on

the specification sheet provided with the unit.

a. Cord-connected units are equipped

with a three-prong (grounding) plug

for your protection against electric

shock.  This must be plugged into a

properly grounded matching receptacle.

b. AFCP-5-7 and AFCP-6-7 field-wired

units connect to the pigtail leads in the

control box.  Wiring must be secured to

the control box with an appropriate

strain relief (provided by installer).

The green ground wire must be

connected to a suitable building ground.

IMPORTANT: 

*BLACK

 wire = Power (HOT)

*WHITE 

wire = Neutral

*GREEN

 wire = Ground

3. Tank and control must be connected to an

appropriate building ground.  Ground

connection will always be marked.

NOTE:  

Field-wired units wire gauge, insulation type 

 and temperature rating, as well as type, size 

 and construction of conduit, must meet or 

exceed applicable specifications of local  

codes and of the National Electrical Code. 

PLUMBING INSTALLATION 

1. Plumb connections must be made in

Compliance with all Federal, State and

Local Plumbing Codes and Ordinances.

IMPORTANT

:  All drain plumbing must be

performed by a qualified plumber.

2. Install provided 1” drain valve on unit drain.

Plumb to an appropriate waste as required by

local plumbing and sanitation ordinances.

WARNING: 

 

 

Electric Shock Hazard 

All servicing requiring access to 

non-insulated electrical 

components must be performed by 

a factory-authorized technician.  

DO NOT open any access panel 

that requires the use of tools.  

Failure to follow this warning can 

result in severe electrical shock. 

CAUTION: 

Risk of Damage 

DO NOT connect or energize this 

appliance until all installation 

instructions are read and followed.  

Damage to the appliance will result 

if these instructions are not 

followed. 

CAUTION

Electrical Shock Hazard 

Cord-connected units are 

equipped with a three-prong plug 

for your protection against 

electrical shock.  Never cut the 

large round prong from the plug, 

or twist a blade to fit an existing 

receptacle. 

IMPORTANT:

 

Contact a licensed electrician 

to install the correct circuit and 

receptacle (cord-connected 

units) or to install and connect 

electrical power (field-wired 

units). 

IMPORTANT

Содержание AFCP Series

Страница 1: ...ERATION MANUAL AFCP SERIES DROP IN REFRIGERATED COLD PANS AFCP MODELS AFCP 1 AFCP 1 7 AFCP 2 AFCP 2 7 AFCP 3 AFCP 3 7 AFCP 4 AFCP 4 7 AFCP 5 AFCP 5 7 AFCP 6 AFCP 6 7 INCLUDES ST SLOPED UNITS INCLUDES...

Страница 2: ...RANTY STATEMENT USECO equipment is warranted to be free of defects in material and workmanship for a period of 12 months from the date of shipment from the factory Warranty applies to the contiguous 4...

Страница 3: ...ss receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELTY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE If damage is unno...

Страница 4: ...ensure its optimum performance ELECTRICAL REFRIGERATION SPECIFICATIONS CORD CONNECTED MODELS MODELS AFCP 1 2 3 AFCP 1 7 2 7 AFCP 4 AFCP 3 7 AFCP 5 6 AFCP 4 7 VOLTAGE 115 VAC 60 Hz 115 VAC 60 Hz 115 V...

Страница 5: ...ERATING CONTROLS NOTE This is a general arrangement drawing only Actual component positions may vary between units TEMPERATURE CONTROL UNIT USED ONLY ON MODELS AFCP 1 7 AFCP 2 7 AFCP 3 7 AFCP 4 7 AFCP...

Страница 6: ...res is intended for use by qualified technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of t...

Страница 7: ...allation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a conve...

Страница 8: ...tion of conduit must meet or exceed applicable specifications of local codes and of the National Electrical Code PLUMBING INSTALLATION 1 Plumb connections must be made in Compliance with all Federal S...

Страница 9: ...NSER CLEANING page 8 DAILY START UP 1 Turn POWER SWITCH located on condensing unit ON Allow unit to run for approximately 30 minutes to reach operating temperature 2 Add necessary adapter bars or adap...

Страница 10: ...mild detergent 2 Use a plastic scouring pad to remove any mineral deposits 3 Rinse tank thoroughly with a vinegar and water solution to neutralize all detergent or cleanser residue 4 Clean pan adapte...

Страница 11: ...r fins Brush vertically top to bottom Collect and discard all lint and debris gathered from this operation IMPORTANT The fins of the condenser are delicate and easily damaged Use care to brush in a ve...

Страница 12: ...n use only cloth or plastic pads Scrub only in a linear motion along the longest axis of the equipment 3 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated...

Страница 13: ...condensing unit is adjustable Temperature adjustment must be performed by a qualified refrigeration personnel only 3 Normal temperature setting would be 1 F 3 AFC 1 7 thru AFC 6 7 The LCD Display pro...

Страница 14: ...plete programming Programming ends automatically if no keys are pressed for 30 seconds Any settings that have been input to the control will be accepted at that time 6 Control settings are stored in n...

Страница 15: ...R FOR AFCP 4 1PC 22110 PERFORATED BOTTOM PLATE STRAINER FOR AFCP 5 1PC 22111 PERFORATED BOTTOM PLATE STRAINER FOR AFCP 6 1PC 22112 PAN RAIL FOR AFCP 1 7 22696 PAN RAIL FOR AFCP 2 7 22697 PAN RAIL FOR...

Страница 16: ...______________________ TECHNICIAN ______________________ SERVICE COMPANY __________________________________________________________________ ADDRESS _____________________________________ STATE ________...

Отзывы: