INTRODUCTION

 

Thank you for purchasing this 

USECO 

appliance. 

Proper installation, professional operation and consistent maintenance of this appliance will 

ensure that it gives you the very best performance and a long, economical service life. 
This manual contains the information needed to properly install this appliance, and to use and 

care for the appliance in a manner which will ensure its optimum performance. 

ELECTRICAL & REFRIGERATION SPECIFICATIONS 

CORD-CONNECTED MODELS 

MODELS 

AFCP-1, -2, -3        

AFCP-1-7, -2-7 

AFCP-4       

AFCP-3-7 

AFCP-5, -6    

AFCP-4-7 

VOLTAGE 

115 VAC 60 Hz.  115 VAC 60 Hz.  115 VAC 60 Hz. 

TOTAL AMPS 

5.3 A 

7.0 A 

7.5 A 

REFRIGERANT (AMOUNT / TYPE) 

28 oz. / R-134A  24 oz. / R-404A 

32 oz. / R-404A 

PRESSURE (High Side / Low Side) 

440 / 162 psig 

500 / 174 psig 

500 / 174 psig 

PERMANENTLY CONNECTED MODELS 

MODELS 

AFCP-5-7      

AFCP-6-7 

SINGLE PHASE VOLTAGE 

115 VAC 60 Hz. 

TOTAL AMPS 

15.3 A 

MCA / MES / LRA 

21.0A / 30A / 59A 

REFRIGERANT (Amount / Type) 

54 oz. / R-404A 

PRESSURE (High Side / Low Side) 

500 / 174 psig 

Содержание AFCP Series

Страница 1: ...ERATION MANUAL AFCP SERIES DROP IN REFRIGERATED COLD PANS AFCP MODELS AFCP 1 AFCP 1 7 AFCP 2 AFCP 2 7 AFCP 3 AFCP 3 7 AFCP 4 AFCP 4 7 AFCP 5 AFCP 5 7 AFCP 6 AFCP 6 7 INCLUDES ST SLOPED UNITS INCLUDES...

Страница 2: ...RANTY STATEMENT USECO equipment is warranted to be free of defects in material and workmanship for a period of 12 months from the date of shipment from the factory Warranty applies to the contiguous 4...

Страница 3: ...ss receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELTY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE If damage is unno...

Страница 4: ...ensure its optimum performance ELECTRICAL REFRIGERATION SPECIFICATIONS CORD CONNECTED MODELS MODELS AFCP 1 2 3 AFCP 1 7 2 7 AFCP 4 AFCP 3 7 AFCP 5 6 AFCP 4 7 VOLTAGE 115 VAC 60 Hz 115 VAC 60 Hz 115 V...

Страница 5: ...ERATING CONTROLS NOTE This is a general arrangement drawing only Actual component positions may vary between units TEMPERATURE CONTROL UNIT USED ONLY ON MODELS AFCP 1 7 AFCP 2 7 AFCP 3 7 AFCP 4 7 AFCP...

Страница 6: ...res is intended for use by qualified technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This manual is considered to be a permanent part of t...

Страница 7: ...allation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a conve...

Страница 8: ...tion of conduit must meet or exceed applicable specifications of local codes and of the National Electrical Code PLUMBING INSTALLATION 1 Plumb connections must be made in Compliance with all Federal S...

Страница 9: ...NSER CLEANING page 8 DAILY START UP 1 Turn POWER SWITCH located on condensing unit ON Allow unit to run for approximately 30 minutes to reach operating temperature 2 Add necessary adapter bars or adap...

Страница 10: ...mild detergent 2 Use a plastic scouring pad to remove any mineral deposits 3 Rinse tank thoroughly with a vinegar and water solution to neutralize all detergent or cleanser residue 4 Clean pan adapte...

Страница 11: ...r fins Brush vertically top to bottom Collect and discard all lint and debris gathered from this operation IMPORTANT The fins of the condenser are delicate and easily damaged Use care to brush in a ve...

Страница 12: ...n use only cloth or plastic pads Scrub only in a linear motion along the longest axis of the equipment 3 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated...

Страница 13: ...condensing unit is adjustable Temperature adjustment must be performed by a qualified refrigeration personnel only 3 Normal temperature setting would be 1 F 3 AFC 1 7 thru AFC 6 7 The LCD Display pro...

Страница 14: ...plete programming Programming ends automatically if no keys are pressed for 30 seconds Any settings that have been input to the control will be accepted at that time 6 Control settings are stored in n...

Страница 15: ...R FOR AFCP 4 1PC 22110 PERFORATED BOTTOM PLATE STRAINER FOR AFCP 5 1PC 22111 PERFORATED BOTTOM PLATE STRAINER FOR AFCP 6 1PC 22112 PAN RAIL FOR AFCP 1 7 22696 PAN RAIL FOR AFCP 2 7 22697 PAN RAIL FOR...

Страница 16: ...______________________ TECHNICIAN ______________________ SERVICE COMPANY __________________________________________________________________ ADDRESS _____________________________________ STATE ________...

Отзывы: