26
System Start
-
up Instructions
1.
Once all the plumbing has been connected, open the main water shutoff valve.
2.
Plug the Matrixx valve into an approved power source that is constantly energized.
3.
When power is supplied to the control valve, wait for a second while it finds the service posi-
tion.
4.
Once the valve has settled on the time of day, start an Immediate Manual Regeneration
(See page 20 or 26). The valve will immediately start moving to the BACKWASH position.
5.
Open the inlet on the bypass valve slowly and allow water to enter the unit. Allow all air to
escape from the unit before turning the water on fully then allow water to run to drain for the
entire backwash cycle or until all media fines are washed out of the filter indicated by clear
water coming from the drain hose. The peroxide should be injecting during this procedure.
6.
Allow the valve to advance to the RINSE position. Check the drain line flow. Allow the wa-
ter to run for the entire RINSE cycle until the water is clear.
7.
The valve will automatically advance to the SERVICE position after the RINSE cycle is com-
plete. Open the outlet valve on the control valve bypass, then open the nearest treated wa-
ter faucet and allow the water to run until clear, close the tap and replace the faucet screen.