18
1. Plug the chemical pump power cord into a continuously energized 110v outlet. The
chemical pump should be set when the unit is shipped. It should be set to
“5
SEC-
ONDS
”
and the percentage should be set on 50%. If the injection panel is used go to
page 29.
2. If changes need to be made, the pump must be unlocked. If the pump is locked, push
and hold the mode and the %
“
percentage
”
buttons at the same time and hold them for
3
-
5 seconds. The pump locked sentence will disappear. If
“
STANDBY
”
is on the
screen. Push and hold the
“
Mode
”
and
“
Stby
”
buttons and
“
STANDBY
”
will disappear.
3. To change the
“
mode
”
to
“5
SECONDS
”,
hold the mode button while using the up or
down arrows to change the setting.
4. To change the percentage, press and hold the
“%”
button while using the up or down
arrows to change the percentage to the desired rate. The pump is now programmed.
See the
“
Bubble Method
”
for pump adjustment.
5. Once the pump is programmed pour the supplied Hydrogen Peroxide in the chemical
tank. Now push and hold the
“
prime
”
button until the pump pulls the solution from the
container up to the pump and on to the injector. The level can be seen in the tubing as
the pump becomes primed. Once it is primed, the pump is ready to use. The pump will
operate during the startup process. If the pump is not working see below.
NOTE: If the pump is showing
“
Standby
”,
hold the
“
MODE
”
and push the
“
STBY
”
button to take the pump out of the standby mode. The display will not show
“
Standby
”
if it is normal operation. BE SURE to check that the pump is not in the
“
Standby
”
mode. If the pump is left in
“
Standby
”,
it will not operate during regen-
eration as intended. If the pump is
“
Locked
”,
it will need to be unlocked to make
changes. If the valve is
“
Locked
”,
press and hold the
“
MODE
”
and
“%”
button at
the same time for 3
-
5 seconds to unlock.
Chemical Injection Pump Start
-
up Instructions