25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Contact Information

 

 

The Contact Information screes is used to provide the customer with contact info 

for US Water Systems.  There is a link to the website and to our support team.  

 

 

 

 

Regeneration Initiation

 

 

There are two options for regenerating the system.  Tap on the desired option and press 

OK

”.  

 

 

Regenerate Now:  

Regenerate Now will que an immediate regeneration and will start instantly.

 

  

 

Regenerate at Next Regen Time:  

Regenerate at Next Regen Time will que the system re-

generate at the specified regeneration time chose in the programming.  

 

Programming Using Water Logix App

 

Содержание Matrixx 150-FLCS Series

Страница 1: ...systems com US Water Systems Matrixx Liquid Chlorination Water Treatment System Visit us online at www uswatersystems com REVISION 1 2 REVISION DATE February 3 2020 US Water Systems Corporate Office 1209 Country Club Road Indianapolis IN 46234 1 800 608 8792 info uswatersystems com Owners Manual Models 150 FLCS XXXX ...

Страница 2: ...US Water Systems at 1 800 608 8792 to report any shipping damage within 24 hours of delivery Claims made after 24 hours may not be honored Small parts needed to install the system are in a parts bag To avoid loss of the small parts keep them in the parts bag until you are ready to use them Unpacking Inspection Check and comply with your provincial state and local codes You must follow these guidel...

Страница 3: ...equired Use copper brass or PEX pipe and fittings Some codes may also allow PVC plastic pipe ALWAYS install the included bypass valve or 3 shut off valves Bypass valves let you turn off water to the system for repairs if needed but still have water in the house pipes 5 8 OD drain line is needed for the valve drain A length of 5 8 OD drain line tubing is needed for the brine tank over flow fitting ...

Страница 4: ...ow to clean the injection point fitting and check valve Chlorine will frequently crystalize at that injection point and clog or restrict the opening Contact tanks are flushed periodically to remove sludge buildup PROPORTIONAL INJECTION SYSTEM This component mounts on the wall and therefore takes up no floor space It is fully assembled and ready for installation The inlet is on the left and the out...

Страница 5: ...eaction time the water passes through the backwashing carbon filter The backwashing carbon filter uses GAC carbon to remove the oxidized precipitated contaminants As the water passes through carbon filter the contaminants are removed from the water and collected on the carbon media Once the water has passed through the carbon filter the water is iron sulfur and bacteria free Any residual chlorine ...

Страница 6: ...ar is installed properly This bar should be secured to the wall studs or wood backing plate that is secured to the wall studs Strainer Filter Sump 30 and 100 Mesh Strainers 1 4 Tubing Spare Pump Tube Weighted Suction Strainer Injection Pump Rain Roof Spare Injection Pump Head Clips Stainless Steel Mounting Bar 3 4 Union Adaptors 1 x 3 4 Bell Reducers Mounting Screws Nuts and Sleeves for 1 4 Tubing...

Страница 7: ...ction panel Use the 3 4 Union Adaptors to connect to the panel These adaptors are designed for 3 4 PVC If 1 plumbing is used the 1 x 3 4 Bell Reducers can be used to adapt the 3 4 Un ion Adaptors to 1 connections A small piece of 3 4 pipe is needed to connect the 1 x 3 4 Bell Reducers to the 3 4 Union Adaptors 1 x 3 4 Bell Reducer 3 4 Union Adaptor 1 Pipe 3 4 Pipe ...

Страница 8: ...trainer filter and the strainer sump If the feed water is high in turbidity use the 100 mesh strainer filter All other applications should use the 30 mesh strainer filter Insert the strainer filter in the strainer head on the panel then install the strainer sump and turn it clockwise until hand tight Use both hands to tighten the strainer sump Do not use tools to tighten the strainer sump ...

Страница 9: ...st the chlorine injection level See the drawing on page 31 3 Connect a ball valve to the dump port see figure on page 7 on the retention tank and convey a pipe or hose from this valve to a dump pipe or pit This will be used periodically to dump any accumulated sludge from the retention tank 1 There is a ball valve on the bottom of the strainer filter sump This ball valve should be closed during op...

Страница 10: ...10 Retention Tank Installation ...

Страница 11: ...ant criteria in sizing a filter is the confirming the flow rate available for backwashing The water must pass through the filter media at the proper service flow rate but it also must be backwashed at the proper flow rate as well Some of the media will actually require a higher backwash rate than the specified service flow rate The filter must be backwashed at a flow rate sufficient to dislodge an...

Страница 12: ...12 Carbon Filter Flow Diagram US Water Backwashing Filters Outlet to Sediment Filters Inlet from Retention Tank s ...

Страница 13: ...PLUMBING Condition of existing plumbing should be free from lime and iron buildup Piping that is built up heavily with lime and or iron should be replaced LOCATION OF FUSION TANK AND DRAIN The tank should be located close to a drain to prevent air breaks and back flow CAUTION Water pressure is not to exceed 80 psi water temperature is not to exceed 110 F 43 C and the unit cannot be subjected to fr...

Страница 14: ... procedure Pour all the gravel and all the media shipped with the unit into the tank US Water does not send extra unused media 5 When media is installed move tank side to side to settle the media Remove the funnel and tape from the distributor tube It is a good practice to soak the media prior to startup If the tank is filled with water at this time it can be soaking while the rest of the install ...

Страница 15: ...ng the basket clockwise to lock it in place Place the upper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not to cross thread the valve on the tank 8 Tighten the valve hand tight then snug it further by tapping it with the palm of the hand DO NOT use tools to tighten the valve or damage could occur ...

Страница 16: ...cting any piping to the valve Always leave at least 6 152 mm between the control valve and joints being soldered when soldering pipes that are connected to the valve Failure to do this could cause damage to the valve The Backwashing Filter is equipped with 1 female pipe threaded ports on the control valve by pass The bypass is marked with arrows to show proper flow direction The arrow pointing to ...

Страница 17: ...ed of larger diameter than the drain line This linear pipe should have a physical drop toward the drain 1 2 10 The goal is to have a gravity drain without much back pressure when traveling long distances NOTE A DIRECT CONNECTION INTO A WASTE DRAIN IS NOT RECOMMENDED A PHYSICAL AIR GAP OF AT LEAST 1 5 SHOULD BE USED TO AVOID BACTERIA AND WASTEWATER TRAVELLING BACK THROUGH THE DRAIN LINE INTO THE SY...

Страница 18: ...ackwash cycle lasts up to 25 minutes During this time water can be heard running intermittently to the drain New Sounds Automatic Hard Water Bypass During Regeneration In the case of emergency the system can be isolated from the water supply using the bypass valve located at the back of the control In normal operation the bypass is open with the handle in line with the inlet and outlet pipes To is...

Страница 19: ...splay reads 0000 Regeneration cycle will initiate at the next designated regeneration time 2 To start Immediate Extra Cycle First complete above step With Gallons Remaining Until Next Regeneration at 0000 Press and hold the Set Change button After 3 seconds the regeneration cycle will begin 3 To Fast Cycle thru regeneration First complete above 2 steps Note Press and hold the Set Change button for...

Страница 20: ...d the next menu item will flash 4 To set the Number of Days between Backwash Cycles A press the Set Changebutton Repeat instructions from step 2 Notes 1 Maximum value is 29 2 If value set to 0 Automatic Backwash will never occur 3 Default setting is 7 days for filters 5 To Exit Main Menu press the Menu Enter button Note If no buttons are pressed for 60 seconds the Main Menu will be exited automati...

Страница 21: ... Logix Bluetooth app 1 Go to the App store on the phone to be used and search for Water Logix 2 Download the free Water Logix app 3 Open the app to begin programing 4 Once the app is open it will begin scanning for control valves in the Bluetooth vicinity 5 Once the app connects to the control valve or valves they will appear on the screen Each valve can be renamed by tapping on the three vertical...

Страница 22: ...e time will change to the current time of the device 2 Backwash Frequency Tap on the Filter Backwash Frequency box and input the de sired days between backwashing Most municipal applications should set this to 7 days Some conservative applications can be set as far as 14 days but 7 days is recommended 3 Regeneration Time Tap on the Regeneration Time box Input the desired regeneration time for norm...

Страница 23: ...p on the orange font then use the keyboard that appears to change the value 4 Backwash This should be set to 10 mins and should not be changed 5 Rest This should be set to 2 mins and should not be changed 6 Rapid Rinse This should be set to 10 mins and should not be changed Programming Using Water Logix App ...

Страница 24: ... reset 1 Total Regenerations This parameter shows how many times the system has regenerat ed since it was put in service or since the last time the value was reset 2 Total Water Treated This parameter shows the total amount of water that has been treated since the system was put in service or since the last time the value was reset Programming Using Water Logix App ...

Страница 25: ...eneration Initiation There are two options for regenerating the system Tap on the desired option and press OK Regenerate Now Regenerate Now will que an immediate regeneration and will start instantly Regenerate at Next Regen Time Regenerate at Next Regen Time will que the system re generate at the specified regeneration time chose in the programming Programming Using Water Logix App ...

Страница 26: ...Once 1 2 ppm of chlorine stays consistent the chlorine injection system is adjusted properly 1 2 ppm of residual chlorine is an indicator that there is a small amount of residual chlo rine in the treated water and the contaminant is being oxidized Once this setting is de termined the system will operate automatically Over the first 1 3 months it is important to monitor the chlorine level in the st...

Страница 27: ... water will become cleaner and the initial dosage of chlorine may need to be adjusted to compensate for the lower contaminant level once the build up is removed Routine Maintenance Pressure Tank If your plumbing system uses a bladder pressure tank it will be in the system prior to the Fusion Liquid Chlorination system This tank should be drained periodically to remove build up of contaminants Typi...

Страница 28: ...needed 1 5 Years 411 UCCVDBO Chlorine Solution Tank Periodically check the solution level and refill as needed Varies by wa ter usage and quality 710 PELLETS Retention Tank s Blow down retention tanks peri odically to remove sludge from contaminant build up Varies by wa ter usage and quality N A Carbon Tank Check the clock and settings periodically or after a power out age 4 Months N A Carbon Tank...

Страница 29: ...29 Flow Schematic ...

Страница 30: ...teration or accident or to any damage caused by fire flood freezing Acts of God or any other casualty or if the original serial numbers have been removed Fouling or damage to the resin caused by iron sulfur bacterial iron silt sand tannins or ganics bacteria hot water or chlorine voids the warranty on resin These warranties are in lieu of all other warranties expressed or implied and we do not aut...

Отзывы: