LIMITED WARRANTY 
 

US Water Systems, Inc. warrants the GreenWave system as follows: 

 

The Tank is warranted to be free of defects in materials and workmanship for life from the date of 
original installation. 

 

The Head is warranted to be free of defects in materials and workmanship for life  from date of 
original installation. 

 

The Filter Housing and all other parts not mentioned here is warranted to be free from defects in 
materials and workmanship for five years from the date of the original installation 

 

The GreenWave NAC media is warranted for performance for a period of five  years from the date of 
the original installation. 

Conditions 

1. 

The GreenWave system must be properly installed in accordance with the instructions provided by US 
Water Systems.

 

2.  Any component failure must not result from abuse, fire, freezing or other acts of nature, violence, or 

improper installation. 

3.  Equipment must be installed and operated in compliance with the local plumbing codes, and on an 

approved water supply. 

4.  Equipment is limited to use at water pressures not to exceed 100 PSI and temperatures not to exceed 

110 degrees F. 

5.  Water supply must not exceed 0.5-PPM chlorine. For water supply exceeding 0.5 PPM chlorine, 

pretreatment is required. (Please contact your water treatment specialist.) 

6.  Information, including model number, serial number, and date of installation, must be provided for 

any claims pertaining to equipment in warranty. 

7.  Defective parts are subject to inspection by either US Water Systems, Inc. or any authorized 

representative before final commitment of warranty adjustment is made. 

8.  US Water Systems, Inc. reserves the right to make changes or substitutions in parts or equipment 

with material of equal quality or value and of then current production. 

Limitations 

Our obligation under this warranty with respect to the tank or valve is limited to furnishing a 
replacement for, or at our option, repairing any part or parts to our satisfaction that prove defective 
within the warranty period stated above. Such replacement parts will be delivered to the owner F.O.B. 
nearest factory, at no cost, excluding freight and local labor charges, if any. 
 
Our obligation under this warranty with respect to the GreenWave media will be limited to furnishing a 
replacement for the media within five years from date of original installation. Such replacement media 
will be delivered to the owner F.O.B. nearest factory, at no cost, excluding freight and local labor 
charges, if any. Damage to the media due to chlorine, other oxidizers or fouling or any other operation 
outside of the limits shown under Specifications, is not covered by this warranty. 
 
US Water Systems, Inc. shall not be liable for freight, handling or labor charges, or consequential 
damages. 

Installation, Operation and Maintenance Manual 

GreenWave System 

Содержание GreenWave 1000

Страница 1: ...GreenWave Residential Systems Chemical Free Salt Free Scale Prevention GreenWave 1000 GreenWave 1500 GreenWave 2000 US Water Systems Inc 1209 Country Club Road Indianapolis IN 46234 1 800 608 8792 sup...

Страница 2: ...tion and Maintenance Manual GreenWave System Table of Contents Introduction 3 System Overview 4 System Specifications 5 Cautions 6 Notes to the Installer 6 Installation and Start Up 7 Note to the Home...

Страница 3: ...and glass is greatly reduced GreenWave is not a water softener low or phosphate free cleaning products are recommended to achieve optimum results Modern surfactant or detergent based liquid soaps are...

Страница 4: ...System Overview Pre Filter Tank Head Media Tank Bypass 3 4 or 1 PVC Assembly Glue Connectors Typical Connection Fittings Installation Operation and Maintenance Manual GreenWave System...

Страница 5: ...al Specifications 1000 1500 2000 Max Service Flow gpm 10 15 20 Dry Weight lbs 30 40 50 Service Weight lbs 95 120 150 Dimensions nominal inches A 52 5 58 5 56 5 B 50 56 54 C 9 10 12 D 2 5 2 5 2 5 E 3 0...

Страница 6: ...e system freeze Damage to the tank and pre filter may result System must be operated in a vertical position Do not lay it down during operation The system may be placed in any position for shipping an...

Страница 7: ...he tank to fill with water Close the supply valve when a steady stream of water comes out of the outlet port 8 Connect the Outlet of the GreenWave system to the cold water supply to the home 9 Open th...

Страница 8: ...mpoos lather more than with untreated water Soaps and shampoos will also rinse off much easier and faster than they would with traditional soft water We recommend the use of modern soaps for the best...

Страница 9: ...ng model number serial number and date of installation must be provided for any claims pertaining to equipment in warranty 7 Defective parts are subject to inspection by either US Water Systems Inc or...

Страница 10: ...Installation Operation and Maintenance Manual GreenWave System...

Страница 11: ...er which has been subjected to misuse neglect alteration or accident or to any damage caused by fire flood freezing Acts of God or any other casualty or if the original serial numbers have been remove...

Отзывы: