Control Operation During A Power Failure

 

In the event of a power failure, the valve will keep track of the time and day for 48 hours.  
The programmed settings are stored in a non-volatile memory and will not be lost during a 
power failure.  If power fails while the unit is in regeneration, the valve will finish regenera-
tion from the point it is at once power is restored.  If the valve misses a scheduled regenera-
tion due to a power failure, it will queue a regeneration at the next regeneration time once 
power is restored. 

Main Display

 

About The System 

Periodically the filter will require a back wash to clean the trapped particles and unpack the 
filter bed to restore the system flow rates.  The table below explains the regeneration steps. 

Regeneration Process

 

Step

Name

Description

#1

Back Wash

Fresh water is introduced to the bottom of the tank flowing upwards expanding 
the filter media to rinse out any dirt or small particles to the drain and to un-
compact the bed to restore full service flow rates.

#2

Rinse

Fresh water is introduced from the top of the tank flowing down through the 
filter bed rinsing any unfiltered water to the drain.

The main display page will pause on the Date and Time page for 5 seconds.  Then it will 
continually  scroll  through  all  of  the  system  diagnostic  display  pages.    Depending  on  the 
Valve Type some pages will not be displayed.  To manually scroll through the diagnostics, 
press the down or up key.  To reset the TOTAL REGENS, TOTAL GALLONS OVER RUN 
TOTAL, or PEAK flow rates, press and hold the MENU until the value changes to zero. 

PARAMETER

DESCRIPTION

JULY/17/2012

8:30 PM

TOTAL 1,500 GAL

REMAIN 1,200 GAL

LAST REGEN

9/24/12

TOTAL REGENS

10

TOTAL GALLONS

001590 GAL

TOTAL 4 DAYS

REMAIN 3 DAYS

OVER RUN TOTAL

0000 GAL

CURRENT 1.5 GPM

PEAK 6.5 GPM

DELAYED REGEN

OFF

REGEN TIME

12:00 AM

VALVE MODE

B.W. FILTER

The current setting for regeneration time.

The current setting of the valve mode.

The total number of regenerations.

The total amount of gallons treated by the system.

The total amount of water that has exceeded the system capacity over the last 4 
regenerations.  When remaining goes to zero, the gallons used will be added to over run total.
The current flow rate and the peak flow rate since the last regeneration.

Advises whether a delayed regeneration has been scheduled manually or automatically.

Month, Day, Year, Time

The number of days remaining before regeneration.  This option is only in filter mode.

The total amount is the system capacity when fully regenerated.  The remaining is the 
capacity left in the system.
The date of the last regeneration.

Содержание FSF-150

Страница 1: ...id pinched o rings during installation by applying provided with install kit NSF certified lubricant to all seals 3 This system is not intended for treating water that is microbiologically unsafe or o...

Страница 2: ...y damage or personal injury Be sure to check the entire unit for any shipping damage or missing parts Also note damage to the shipping cartons Contact US Water Systems at 1 800 608 8792 for all damage...

Страница 3: ...and ordinances Use only lead free solder and flux for all sweat solder connections as required by state and federal codes Maximum allowable inlet water pressure is 125 psi If daytime pressure is over...

Страница 4: ...4 Specifications...

Страница 5: ...make product improvements which may deviate from the specifications and descriptions stated herein without obligation to change previously manufactured products or to note the change Peak flow rates a...

Страница 6: ...5 8 OD drain line is needed for the valve drain Sizing Requirements Water Pressure The water system must have a pump large enough to deliver the recommended backwash rate with a minimum pressure at t...

Страница 7: ...ut the filter in a place water damage is least likely to occur if a leak develops The manufacturer will not repair or pay for wa ter damage A 120 volt electric outlet to plug the includ ed transformer...

Страница 8: ...ing plumbing should be free from lime and iron buildup Piping that is built up heavily with lime and or iron should be replaced LOCATION OF FUSION NLT TANK AND DRAIN The Infusion tank should be locate...

Страница 9: ...tank and pour slow enough to keep from plugging the hole A helper may be needed to hold the funnel during the filling process It is recom mended that a dust mask and safety goggles be worn to prevent...

Страница 10: ...s then turning the basket clockwise to lock it in place Place the upper basket over the distributor tube and push the valve on the tank Thread the valve on the tank by turning it clockwise Be sure not...

Страница 11: ...AND OUTLET PIPING TO MAINTAIN GROUNDING WHEN APPLICABLE Any solder joints being soldered near the valve must be done before connecting any piping to the valve Always leave at least 6 152 mm between t...

Страница 12: ...f running the drain line more than 20 ft overhead it is recommended to increase the hose size to 3 4 A DIRECT CONNECTION INTO A WASTE DRAIN IS NOT RECOMMENDED A PHYSICAL AIR GAP OF AT LEAST 1 5 SHOULD...

Страница 13: ...ter tap nearby remove the faucet screen open the faucet and let water run a few minutes or until the system is free of any air or foreign material resulting from the plumbing work 7 Make sure there ar...

Страница 14: ...14 Filter Installation...

Страница 15: ...drain line flow Allow the water to run for 3 4 minutes or until the water is clear 6 The valve will automatically advance to the SERVICE position after the RINSE cycle is complete Open the outlet valv...

Страница 16: ...ault value is OFF This should not be changed REGEN TIME This setting determines the time of day to perform a scheduled regenera tion The normal regen time for a filter is 12 00 AM Settings Press SETIN...

Страница 17: ...nd Time page for 5 seconds Then it will continually scroll through all of the system diagnostic display pages Depending on the Valve Type some pages will not be displayed To manually scroll through th...

Страница 18: ...normal operation the bypass is open with the on off knobs in line with the inlet and outlet pipes To isolate the filter simply rotate the knobs clockwise as indicated by the word BYPASS and arrow unti...

Страница 19: ...0048 TOP CONE D 1 25020041 844 TANK 75 E 1 25020042 948 TANK 100 E 1 25020043 1054 TANK 150 E 1 25010058 1252 TANK 200 E 1 25030007 1465 TANK 300 E 1 50010005 DISTRIBUTOR 1X54 F 1 REPLACEMENT PARTS FI...

Страница 20: ...20 Filter Exploded View...

Страница 21: ...BOW A 2 60010019 1 NPT STRAIGHT A 2 60010023 3 4 NPT STRAIGHT A 2 60010079 VALVE COUPLING INLET B 1 60010101 VALVE COUPLING OUTLET METER SIDE C 1 60010025 PLASTIC SECURE CLIP D 2 60010046 BYPASS SS CL...

Страница 22: ...TOR SET 00 VIOLET 60010130 85HE SEAL SPACER KIT 60010034 INJECTOR SET 0 RED 60010131 85HE DLFC 1 1 5 GPM 60010033 INJECTOR SET 1 WHITE 60010132 85HE DLFC 2 2 0 GPM 60010032 INJECTOR SET 2 BLUE 6001013...

Страница 23: ...A20 1 5056063 O Ring 78 74 5 33 A21 1 26010103 O Ring 25 3 55 A22 1 7060007 Valve Bottom Connector A23 1 13000426 Screw ST2 9X13 Large Washer A24 2 5031022 O Ring 32 3 A25 1 5031021 O Ring 18 3 A26 1...

Страница 24: ...24 Power Head Exploded View...

Страница 25: ...0426 Screw ST2 9X13 Large Washer A24 2 5056139 Washer 3x13 B09 1 5030007 BNT85 Main Gear B10 1 5030005 BNT185 Housing B11 1 5031017 BNT85HE Brine Gear Downflow B12 1 5010023 Magnet 3 2 7 B13 1 5056141...

Страница 26: ...k if central tube is cracked or o ring is damaged Replace faulty parts 8 Internal valve leak Replace valve seals spacer and piston assembly 1 Iron or scale build up in line feeding unit Clean pipes 2...

Страница 27: ...27 Pressure Differential Gauge Installation...

Страница 28: ...od freezing Acts of God or any other casualty or if the original serial numbers have been removed These warranties are in lieu of all other warranties expressed or implied and we do not authorize any...

Отзывы: