Product Features
The backlight on the screen will go off automatically after one minute if no buttons are
pressed. To light it up again press any button on the touch pad.
Reg. remaining time
Display in Service
Meter Delay Regeneration Mode
The display will show the current time and the
remaining treated water alternatively. When the
remaining treated water counts down to zero the
display changes to the regeneration time set by
the user.
1 1 : 3 0
1 2 0 g a l
1 1 : 3 0
0 2 : 1 8
Backlight Screen
Memory during power failure
All program settings are stored in permanent memory. Current valve position, cycle step
elapsed, time of day are stored during the power failure. Reset the current time is necessity
when power up.
If the valve stopped at a regeneration stage when power failure, the valve will return to prior
position when power up. It takes 4 to 5 minutes to reset to the position.
The display shows as:
The system will show the status
when power failure after finding the
position of the valve.
1 1 : 3 0
R e s e t
Restore factory settings
1 1 : 3 0
R e s e t
1) Pull out the power
2) Press the button and plug in
the power simultaneously
3) Release the button
The system is now restored.