5
FOR SAFE OPERATION
A. READ INSTRUCTIONS CAREFULLY: Read and adhere to these instructions. Do not allow anyone who has not
read the instructions to assemble, light, adjust or operate the heater.
B.
Use only in accordance with local codes or, in the absence of local codes, with the standard for the Storage
and handling of Liquefied Petroleum Gases ANSI/NFPA 58 and CSA B 149.1, Natural Gas and Propane
Installation Code.
C.
PROPANE IS VERY FLAMMABLE: In the event of a leak, propane will accumulate and the possibility of a fire
is present. Propane gas is scented and its strong odor is readily detectable. Never strike a match or bring
any flame or create an electric spark in an enclosure when you smell propane gas. Ventilate the area
thoroughly, move the heater outside, find and correct the source of the leak before attempting to light any
appliance. If you are unsure of these instructions evacuate immediately and call for help.
D.
GAS LEAKAGE: If the leak cannot be corrected do not tamper with the heater, follow the shut down
instructions and return the heater to the dealer or address given on last page.
E.
LEAK DETECTION: Before each use of the heater check all fittings and connections with a soap solution to be
sure there are no leaks. NEVER USE ANY FLAME FOR LEAK TEST.
F. CONNECTING HEATER TO PROPANE CYLINDER: Always connect the heater to the bulk cylinder in the outdoors
or in a well ventilated area. NEVER connect this heater to a cylinder near an open flame.
G. USE OF HEATER: Always operate the heater with the propane cylinder in an upright position on a level
noncombustible surface. NEVER place the cylinder on its side when operating the heater.
H. ATTEND HEATER: Do not leave heater unattended while it is in operation.
I. ALWAYS LIGHT HEATER WITH MATCH OR “SPARKLITE” IGNITER: NEVER attempt to light the heater with a spark
lighter.
J.
DO NOT TAMPER: Should the heater not perform properly, such as little or no heat when operating in the “Hi”
position, or for any other reason, DO NOT ATTEMPT TO REPAIR OR TAMPER with the heater. Any tampering
could make the use of the heater unsafe and dangerous. Return the heater to the dealer or the address
given on last page for repair or replacement.
K.
FOR STORAGE: The heater Hi-Med-Lo-Off regulating valve should always be turned to “off” when the heater
is not in use. Allow at least 15 minutes for cooling before handling and storing. Detach propane cylinder from
heater before storing. DO NOT store propane cylinders indoors or near open flame or heat.
L. DO NOT TRANSPORT OR MOVE APPLIANCE WHILE IN OPERATION. FOLLOW SHUTDOWN AND STORAGE
INSTRUCTIONS TO TRANSPORT OR MOVE THIS APPLIANCE.
WARNING:
KEEP THE HEATER OUT OF THE REACH OF CHILDREN
WARNING:
DO NOT USE THIS HEATER ON BULK TANKS OF GREATER CAPACITY THAN 20 POUNDS LPG (50
POUNDS WATER CAPACITY).
GENERAL INFORMATION
A. These units are high pressure propane appliances and are designed to be connected to a bulk propane
tank.
B.
These heaters are equipped with an automatic Safety Shutoff Valve. The gas flow will automatically stop if
the heater fails to operate for any reason.
C.
Maximum safety and convenience have been built into the Hi-Med-Lo-Off Control Valve/Regulator. The
following table lists the approximate BTU’s consumed and the operating hours you can reasonably expect
from bulk propane cylinders.
D.
These heaters are for temporary heating of buildings under construction, alterations, or repair.
Model
NMTT15
NMTT30
Valve Position BTU Input Hours w/20lb. Tank BTU Input Hours w/ 20lb. Tank
Hi
15,000
28
30,000
14
Med
12,000
36
24,000
18
Lo
10,000
43
10,000
43
Содержание NEWMAC PRO NMTT15
Страница 10: ...10 Notes...
Страница 11: ...11 Notes...