Installing the Courier 2-5
Table 2-1. DIP Switch Settings.
DIP
Switch
Factory
Setting
Setting
Effect
For
More
Info
1
1
OFF
OFF
DTR normal
Ch 6
ON
Ignore DTR
2
OFF
OFF
Verbal result codes
Ch 5
ON
Numeric result codes
3
ON
OFF
Suppress result codes
Ch 5
ON
Display result codes
4
OFF
OFF
Echo offline commands
Ch 2
ON
Don’t echo offline commands
5
ON
OFF
Auto-answer
Ch 3
ON
Don’t auto-answer
6
OFF
OFF
Normal Carrier Detect
Ch 6
ON
Carrier Detect always on
7
OFF
OFF
Display all result codes
Ch 5
ON
Display result codes only when
originating calls
8
ON
OFF
Ignore AT commands (dumb mode)
Ch 1
ON
Act on AT commands (smart mode)
9
OFF
OFF
Disconnect on +++
Ch 2
ON
Don’t disconnect on +++
10
OFF
OFF
Load the configuration that is stored in
non-volatile memory (NVRAM)*
Ch 4
ON
Load the &F0 configuration from
read-only memory (ROM)*
IMPORTANT:
When you power ON or reset the Courier, the
DIP switch settings override the settings you may have made
previously using AT commands.
If you change the DIP switch settings while the Courier is
powered ON, you can avoid powering the Courier off to make
the new settings take effect. Just send the Courier the ATZ
command.