23
22
User Manual
Finish charge time is typically 2-4 hours.
Float time is unlimited at 2.23 volts per cell.
Two-Stage Charger (Constant Current-Constant Voltage)*
Following is the chargeing recommendations and charging profile using 2 stage* chargers for US
AGM deep cycle products.
*
Equalization and float charge modes are not considered to be one of the stages in a charge profile.
1. Bulk Charge
Constant current @ maximum bulk charge to 2.45+/-0.05 volts per cell
(e.g. 7.35 volts +/-0.15 volts per 6 volt battery)
2. Absorption Charge
Constant voltage (2.45+/-0.05 vpc) to minimum absorption charge then hold for 2-3
hours
and
terminate
charge.
•
(Optional Float Charge) Constant voltage 2.23+/-0.03 vpc (6.70 volts per 6 volt battery) for unlimited time
•
Equalization Charge
Constant voltage (2.45+/-0.05 vpc) extended for 1-3 hours after normal charge
cycle (repeat every 30 days)
Notes:
Charge time from full discharge is 9-12 hours.
Absorption charge time is determined by the battery but will usually be ˜3 hours at 2.45 volts per cell.
Finish charge time is typically 2-4 hours.
Float time is unlimited at 2.23 volts per cell.
DIAGRAM 7
4
CHARGING AND
EQUALIZING
2.900
3.000
3.100
20
22
24
18
16
14
12
10
8
6
4
2
0
0
1
2
3
4
5
6
7
8
9
10
2.800
2.700
2.600
2.500
2.400
2.300
2.200
2.100
2.000
1.900
3-STAGE AGM CHARGE CURVE WITH PULSE FINISH
Stage 1
Stage 2
Finish Phase
Charge
Current
Charge
Voltage
AGM 3-STAGE CHARGING WITH PULSE FINISH
2.0
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.0
0
2
4
6
8
10
12
14
16
18
20
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Charge V
oltae (volts per cell)
Charge Current (Amps as % of C/20
Ah)
Charge Time (Hours)
US Battery Recommended Charge Profile
2-Stage
(Constant Current - Constant Voltage)
Equalization Charge Current
Charge Voltage
Equalization Charge Voltage
Stage 1
Stage 2
Charge Current
Bulk
Charge
(Constant Current
@
~
10% of C/20Ah)
w/ Max. Voltage and/or
- V termination
Absorption
Charge
(Constant Voltage
@2.45+/-0.05 vpc)
Equalization
Charge
(Constant Voltage)
(1-3 Hours)
(
~
Every 30 cycles)
w/ Maximum Time
Termination at 2-3
hours after Current of
≤
3% of
C/20 Ah is
Reached
AGM 2-STAGE CHARGING
TABLE 5
Example of voltage settings for deep-cycle AGM lead acid batteries using a 2-stage
charger
2-Stage Charger Settings for Deep-Cycle AGM Batteries
System Voltage
6 Volt
8 Volt
12 Volt
24 Volt
36 Volt
48 Volt
Bulk Charge
Voltage
7.2 - 7.35
9.6 - 9.8
14.4 - 14.7 28.8 - 29.4 43.2 - 44.1
57.6 - 58.8
Absorption
Charge Voltage
7.2 - 7.35
9.6 - 9.8
14.4 - 14.7 28.8 - 29.4 43.2 - 44.1
57.6 - 58.8
Absorption Time
2-3 hours
Float Voltage
6.7
9
13.5
27
40.5
54
Equalization
Voltage
7.35
9.8
14.7
29.4
44.1
58.8
Equalization
Time
5-6 hours
Equalization
Frequency
At least once a month; Every two weeks if cycled daily.
DIAGRAM 8
Содержание US 13-4-1 XC2