UG87-LW User Guide
18
2.9 Mounting the Gateway
The gateway can be placed on a desktop or mounted to a wall or a DIN rail.
2.9.1 Wall Mounting (Measured in mm)
Use 2 pcs of M3×6 flat head Phillips screws to fix the wall mounting kit to the gateway, and
then use 2 pcs of M3 drywall screws to mount the gateway associated with the wall
mounting kit on the wall.
Recommended torque for mounting is 1.0 N. m, and the maximum allowed is 1.2
N.m.
2.9.2 DIN Rail Mounting (Measured in mm)
Use 2 pcs of M3×6 flat head Phillips screws to fix the DIN rail to the gateway, and then hang
the DIN rail on the mounting bracket. It is necessary to choose a standard bracket.
Recommended torque for mounting is 1.0 N. m, and the maximum allowed is 1.2
N.m.