![Ursalink UG87-LW Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/ursalink/ug87-lw/ug87-lw_user-manual_1063166128.webp)
UG87-LW User Guide
128
5.10 Events Application Example
Example
In this section, we will take an example of sending alarm messages by email when the
following events occur and recording the event alarms on the Web GUI.
Events
Actions to make events occur (for test)
Cellular network is connected.
Insert SIM card.
Cellular network is disconnected.
Remove SIM card.
WAN cable is connected.
Plug WAN cable.
WAN cable is disconnected.
Unplug WAN cable.
Configuration Steps
1. Go to “System > Events > Events Settings” and enable Event settings.
2. Check corresponding events for record and email alarm, and then click “Save” button as
below. Click “Email Settings” and go to SMTP settings.
Configure the corresponding parameters including email sending settings and recipients as
below. Click “Save” and “Apply” button to make the changes take effect.