Ursalink EM500-SMT Series Скачать руководство пользователя страница 3

EM500-SMT User Guide

3

Contents

1. Overview

..........................................................................................................................................

5

1.1 Description

............................................................................................................................

5

1.2 Features

.................................................................................................................................

5

1.3 Specifications

.........................................................................................................................

5

1.4 Dimensions(mm)

...................................................................................................................

6

2. Hardware Introduction

....................................................................................................................

6

2.1 Packing List

............................................................................................................................

6

2.2 Product Overview

..................................................................................................................

7

3. Sensor Connection with EM500

......................................................................................................

7

4. Sensor Installation

...........................................................................................................................

8

4.1 Soil Sensor Installation

..........................................................................................................

8

4.1.1 Horizontal Installation

................................................................................................

8

4.1.2 Vertical Installation

.....................................................................................................

9

4.2 EM500 Installation

..............................................................................................................

10

4.2.1 Wall Mounting

..........................................................................................................

10

4.2.2 Pole Mounting

..........................................................................................................

10

4.2.3 DIN Rail Mounting

....................................................................................................

10

5.Turn ON/OFF the Sensor

................................................................................................................

11

5.1 Turn ON/OFF via Smartphone APP

.....................................................................................

11

5.2 Turn ON/OFF via PC Software

.............................................................................................

12

5.3 Turn ON/OFF via Button

......................................................................................................

14

6.Sensor configuration

......................................................................................................................

14

6.1 Configuration via Smartphone APP

.....................................................................................

14

6.1.1 Read Configuration

..................................................................................................

14

6.1.2 Write Configuration

..................................................................................................

15

6.1.3 Template Settings

.....................................................................................................

16

6.2 Configuration via PC

............................................................................................................

18

6.2.1 Read Configuration

..................................................................................................

18

6.2.2 Write Configuration

..................................................................................................

18

6.2.3 Upgrade

....................................................................................................................

19

6.2.4 Template and Reset

..................................................................................................

20

7.Sensor Parameters (for App and PC)

..............................................................................................

22

7.1 LoRa WAN Settings

..............................................................................................................

22

7.1.1 Basic Settings-OTAA

..................................................................................................

22

7.1.2 Basic Settings-ABP

....................................................................................................

23

7.1.3 Channel Settings

.......................................................................................................

24

7.2 Device Settings

....................................................................................................................

26

7.2.1 General

.....................................................................................................................

26

7.2.2 Data Calibration

........................................................................................................

26

7.2.3 Threshold

..................................................................................................................

27

8.Sensor Management via Ursalink Cloud

........................................................................................

27

8.1 Ursalink Cloud Registration

.................................................................................................

27

Содержание EM500-SMT Series

Страница 1: ......

Страница 2: ...n closing the lid make sure the lid is fitted the right way so that the enclosure is properly sealed When installing the battery please install it accurately not reversely or with wrong model The devi...

Страница 3: ...FF via Smartphone APP 11 5 2 Turn ON OFF via PC Software 12 5 3 Turn ON OFF via Button 14 6 Sensor configuration 14 6 1 Configuration via Smartphone APP 14 6 1 1 Read Configuration 14 6 1 2 Write Conf...

Страница 4: ...EM500 SMT User Guide 4 8 2 Add a Ursalink LoRaWAN Gateway 28 8 3 Add EM500 SMT to Cloud 29...

Страница 5: ...er can obtain sensor data and view the trend of data change through Ursalink Cloud or thr ough the user s own Network Server 1 2 Features Suitable for multiple agricultural applications Up to 11km com...

Страница 6: ...Waterproof connector and sensor are not included Mounting Pole wall DIN rail 1 4 Dimensions mm 2 Hardware Introduction 2 1 Packing List 1 EM500 SMT Include cable and sensor 2 Mounting Screws 1 Hose C...

Страница 7: ...eparated Front View LoRa Antenna Internal NFC Area Water proof Connector Back View Battery Internal Wall Mounting Holes Pole Mounting Holes 2 Pass the cable through the cap rubber seal and enclosure c...

Страница 8: ...2 At the installation depth shave off some soil from the vertical soil surface exposing undisturbed soil 3 Insert the sensor into the undisturbed soil surface until the entire sensor is inserted The...

Страница 9: ...d the sensor cable in the process Installation Note Abnormal data may show up if sensor prongs are exposed in the air It is possible to get sticks bark roots or other material stuck between the sensor...

Страница 10: ...4 2 2 Pole Mounting 1 Loosen the hose clamp by turning the locking mechanism counter clockwise 2 Straighten out the hose clamp and slide it through the rectangular holes in the mounting bracket wrap t...

Страница 11: ...PP 1 Download Ursalink configuration APP Toolbox and install it on your smartphone The smartphone must support NFC 2 Enable NFC on the smartphone and open the APP 3 Attach the smartphone with NFC area...

Страница 12: ...der that you can get the best connectivity as possible when turning on or off via NFC No response can be caused by long distance wrong location or rapid movement 5 2 Turn ON OFF via PC Software 1 Down...

Страница 13: ...ide 13 4 Device information will be shown on the software 5 Click Power On to turn on the device or Power Off to turn off the device 6 Enter password default password 123456 and press Enter key to cha...

Страница 14: ...Over 10 seconds 6 Sensor configuration Ursalink EM500 SMT sensor can be monitored and configured via NFC technology In order to protect the security of sensor password validation is required when tur...

Страница 15: ...area to the device until the APP shows Read Successful Note Failing to read can be caused by long distance wrong location or rapid movement 6 1 2 Write Configuration 1 Open APP Toolbox and go to Setti...

Страница 16: ...re join the network if LoRaWAN paramters are changed Note Failing to write can be caused by long distance wrong location or rapid movement 6 1 3 Template Settings Template settings are used for easy...

Страница 17: ...h NFC area to another device 3 Select the template file from Toolbox APP and click Write 4 Enter password of this device and keep the two devices close until the APP shows Write successful 5 Slide the...

Страница 18: ...d to read current information of device 3 Attach the device to the NFC reader until Toolbox shows success Note Failing to read can be caused by long distance wrong location or rapid movement 6 2 2 Wri...

Страница 19: ...ation or rapid movement 6 2 3 Upgrade 6 2 3 1 Upgrade Locally 1 Download firmware to your computer 2 Go to Maintenance Upgrade in Toolbox 3 Click Browse and select the firmware from computer 4 Click U...

Страница 20: ...upgrade Note Keep the two devices close and don t move them in order that you can get the best connectivity as possible when upgrading Failing to upgrade can be caused by long distance wrong location...

Страница 21: ...00 SMT User Guide 21 3 Click Browse to select the correct template from computer 4 Click Import to import the template to the device 6 2 4 2 Reset Click the Reset to reset the setting to factory defau...

Страница 22: ...TAA Over the Air Activation For over the air activation end devices must follow a join procedure prior to participating in data exchanges with the network server An end device has to go through a new...

Страница 23: ...7 1 2 Basic Settings ABP Location Ursalink ToolBox PC LoRaWAN Settings Basic Ursalink ToolBox APP Device Settings LoRaWAN Setting Basic Settings ABP Item Description Default App EUI Enter the applicat...

Страница 24: ...ce It is used by both the application server and the end device to encrypt and decrypt the payload field of application specific data messages 5572404c696 e6b4c6f5261 3230313823 Confirmed Mode After s...

Страница 25: ...AU915 Enter the index of the channel to be enabled in the input box separated by commas Example 1 40 Enabling Channel 1 and Channel 40 1 40 Enabling Channel 1 to Channel 40 1 40 60 Enabling Channel 1...

Страница 26: ...2 1 General Location Ursalink ToolBox PC Device Settings General Ursalink ToolBox APP Device Settings General Settings Device General Settings Item Description Default Device Type Show the type of the...

Страница 27: ...e value to network server if it goes above below moisture thresholds Disabled Over Enter the maximum moisture threshold Null Below Enter the minimum moisture threshold Null Example Set the Lockout Tim...

Страница 28: ...EM500 SMT User Guide 28 8 2 Add a Ursalink LoRaWAN Gateway 1 Enable Ursalink type network server and Ursalink Cloud mode in gateway web GUI Note Ensure gateway has accessed the Internet...

Страница 29: ...of Ursalink Cloud and click Add to add gateway to Ursalink Cloud via SN 3 Check if gateway is online in Ursalink Cloud 8 3 Add EM500 SMT to Cloud 1 Go to Device My Devices and click Add Device Fill in...

Страница 30: ...EM500 SMT User Guide 30 2 After EM500 SMT is connected to Ursalink Cloud Click or History Data to check the data on Ursalink cloud 3 Go to Dashboard page to add dashboard END...