![Ursalink EM500-SMT Series Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/ursalink/em500-smt-series/em500-smt-series_user-manual_1063148022.webp)
EM500-SMT User Guide
22
7.Sensor Parameters (for App and PC)
7.1 LoRa WAN Settings
7.1.1 Basic Settings-OTAA
Location:
Ursalink ToolBox(PC): LoRaWAN Settings → Basic
Ursalink ToolBox(APP): Device → Settings → LoRaWAN Settings
Basic Settings-OTAA
Item
Description
Default
App EUI
Enter the application EUI.The Network Server receives
request and consults the entity associated with the
APP EUI to validate the request.If permission is
granted, it responds with a join-accept message.
24e124c000
2a0001
Join Type
Select from: "OTAA" and "ABP".
OTAA:Over-the-Air Activation.
For over-the-air activation, end-devices must follow a
join procedure prior to participating in data exchanges
with the network server. An end-device has to go
through a new join procedure every time it loses the
session context information.
ABP: Activation by Personalization.
Under certain circumstances, end-devices can be
activated
by
personalization.
Activation
by
personalization directly ties an end-device to a specific
network by-passing the join request - join accept
procedure.
OTAA
Application Key
Enter the application key. Whenever an end-device
joins a network via over-the-air activation, the
application key is used to derive the Application
Session key.
5572404c69
6e6b4c6f526
1323031382
3