background image

6

DS1148-003

DELETING A CODE

Access programming mode.

Enter configuration code 

99 nn

 where:

99

  identifies the function code to be deleted

nn

  defines  the  code  memory  location;  possible 

values from 01 to .

Press 

 

to confirm.

The device will beep three times and the red LED 

will blink three times.

If the entered code is wrong, the device will beep 

twice in rapid succession and wait for the correct 

code to be entered.

CODE CHANGE PASSWORD 

PROGRAMMING PROCEDURE 

The code edit password may only be used to edit the 

activation  codes  without  accessing  programming 

mode. 

Access programming mode

Enter configuration code 

36 xxxxxxxx 

where:

36

  

identifies the password change function 

code

xxxxxxxx

 defines  the  new  password  which 

will  replace  the  one  used  to  access 

programming mode. 

Press 

 

to confirm.

The device will beep three times and the red LED 

will blink three times.

If the entered code is wrong, the device will beep 

twice in rapid succession and wait for the correct 

code to be entered.

CHANGING A STORED CODE

Press 

 , 

X

.

Enter the code changing password

Press 

 

to confirm.

The device will beep three times and the red LED 

will light up for confirmation.

Enter configuration code 

90 oooo

 where:

90

 

identifies  the  code  change  function 

code 

ooooo 

is the old activation code

Press 

 to confirm.

Enter the new activation code (from 3 to 8 digits).

Press 

 to confirm.

The device will beep three times and the red LED 

will blink three times.

If the entered code is wrong, the device will beep 

twice in rapid succession and wait for the correct 

code to be entered.

TIMESLOT TERMINAL 

PROGRAMMING PROCEDURE

By  enabling  the  timeslot  function,  a  timer  (not 

included)  may  be  used  to  program  the  periods 

of  the  day  when  to  activate  the  relays  simply  by 

pressing 

.

Access programming mode.

Enter configuration code 

40 a

 where:

40

  identifies the function code to be deleted

a

   defines  the  number  of  relays  enabled  during 

the timeslots.

 

1 = relay 1

 

 = relay 

 

0 = function off 

Press 

 to confirm.

The device will beep three times and the red LED 

will blink three times.

If the entered code is wrong, the device will beep 

twice in rapid succession and wait for the correct 

code to be entered.

  It is not possible to access programming 

mode  during  the  timeslots  in  which 

opening  is  enabled  by  pressing  the 

button

 

 only.

ACTIVATION CODE + 

PASSWORD RESET 

PROCEDURE

Disconnect power from the device.

Hold the programming switch next to the terminal 

board pressed. 

Power the device while the switch is pressed.

Release the switch when you hear a long beep. 

The  device  will  beep  three  times  for  confirmation 

when the switch is released. 

All  the  previously  programmed  codes,  times  and 

passwords will be deleted. 

DEFAULT SETTINGS

Relay 1 

Function   

 

Monostable 

Activation time 

 

00 ms

Button confirmation 

 

No

Relay 2 

Function   

 

Monostable 

Activation time 

 

00 ms

Button confirmation 

 

No

Timeslot terminal   

OFF

Отзывы: