6
DS1148-003
DELETING A CODE
Access programming mode.
Enter configuration code
99 nn
where:
99
identifies the function code to be deleted
nn
defines the code memory location; possible
values from 01 to .
Press
to confirm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
CODE CHANGE PASSWORD
PROGRAMMING PROCEDURE
The code edit password may only be used to edit the
activation codes without accessing programming
mode.
Access programming mode
Enter configuration code
36 xxxxxxxx
where:
36
identifies the password change function
code
xxxxxxxx
defines the new password which
will replace the one used to access
programming mode.
Press
to confirm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
CHANGING A STORED CODE
Press
,
X
,
.
Enter the code changing password
Press
to confirm.
The device will beep three times and the red LED
will light up for confirmation.
Enter configuration code
90 oooo
where:
90
identifies the code change function
code
ooooo
is the old activation code
Press
to confirm.
Enter the new activation code (from 3 to 8 digits).
Press
to confirm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
TIMESLOT TERMINAL
PROGRAMMING PROCEDURE
By enabling the timeslot function, a timer (not
included) may be used to program the periods
of the day when to activate the relays simply by
pressing
.
Access programming mode.
Enter configuration code
40 a
where:
40
identifies the function code to be deleted
a
defines the number of relays enabled during
the timeslots.
1 = relay 1
= relay
0 = function off
Press
to confirm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
It is not possible to access programming
mode during the timeslots in which
opening is enabled by pressing the
button
only.
ACTIVATION CODE +
PASSWORD RESET
PROCEDURE
Disconnect power from the device.
Hold the programming switch next to the terminal
board pressed.
Power the device while the switch is pressed.
Release the switch when you hear a long beep.
The device will beep three times for confirmation
when the switch is released.
All the previously programmed codes, times and
passwords will be deleted.
DEFAULT SETTINGS
Relay 1
Function
Monostable
Activation time
00 ms
Button confirmation
No
Relay 2
Function
Monostable
Activation time
00 ms
Button confirmation
No
Timeslot terminal
OFF