![urmet domus Sinthesi Steel Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/urmet-domus/sinthesi-steel/sinthesi-steel_quick-start-manual_1062641003.webp)
5
DS1148-003
TERMINALS
+~
Power positive (1Vac or 1Vdc)
-~
Power negative (1Vac or 1Vdc)
H
Timeslots
A
Hall door opener relay
A1
Hall door opener relay 1
S1
Common contact relay 1
S3
Normally open contact relay 1
S
Normally closed contact relay 1
S4
Common contact relay
S6
Normally open contact relay
S5
Normally closed contact relay
GND Ground
PROGRAMMING
MASTER PASSWORD
PROGRAMMING PROCEDURE
The master password is required to access device
configuration programming mode.
Power the device.
Press the programming switch next to the terminal
board three times in 6 seconds.
The device will beep three times and the red LED
will light up for confirmation.
Enter the password code (from 3 to 8 digits).
Press
to confirm.
The device will beep three times to confirm. The
red LED will go out and the device will switch to
normal operation.
ACCESSING PROGRAMMING
MODE
Programming mode may be used to configure
operation of the device and to save or edit access
codes.
Press
X
.
Enter the password and press
.
The device will beep three times and the red LED
will light up for confirmation: the device is in
programming mode.
Either hold
X
pressed for at least three second or
leave the device inactive for more than 30 seconds
to quit programming mode.
RELAY OPTIONS
PROGRAMMING PROCEDURE
Access programming mode.
Enter the configuration code
nn a b ss
where:
nn
is the relay to be configured; possible values
are:
31 = relay 1
3 = relay
a
defines whether the code needs to be confirmed
by pressing the button
or not; possible
values are:
1 = relay activation entering the code only
= relay activation entering the code and
pressing the button
to confirm.
b
defines the relay activation mode; possible
values are:
1 = monostable activation
= toggle activation
ss
defines the activation time expressed in
seconds; possible values are:
00 = 00ms (set this value for toggle
operation)
01 = 1 second
..
99 = 99 seconds
Press
to confirm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.
ACTIVATION CODE STORAGE
PROCEDURE
Access programming mode.
Enter configuration code
nn xxxxxxxx
where:
nn
defines the code memory location;
possible values from 01 to .
xxxxxxxx
activation code (from 3 to 8 digits).
Press
to confirm.
Define the number of relays to be activated with the
code shown:
1 = relay 1
= relay
Press
to confirm.
The device will beep three times and the red LED
will blink three times.
If the entered code is wrong, the device will beep
twice in rapid succession and wait for the correct
code to be entered.