urmet domus Sinthesi Steel Скачать руководство пользователя страница 3

5

DS1148-003

TERMINALS

+~

Power positive (1Vac or 1Vdc)

-~

Power negative (1Vac or 1Vdc)

H

Timeslots

A

Hall door opener relay 

A1

Hall door opener relay 1

S1

Common contact relay 1

S3

Normally open contact relay 1

S

Normally closed contact relay 1

S4

Common contact relay 

S6

Normally open contact relay 

S5

Normally closed contact relay 

GND Ground

PROGRAMMING

MASTER PASSWORD 

PROGRAMMING PROCEDURE

The master password is required to access device 

configuration programming mode.

Power the device.

Press the programming switch next to the terminal 

board three times in 6 seconds.

The device will beep three times and the red LED 

will light up for confirmation.

Enter the password code (from 3 to 8 digits).

Press  

 to confirm.

The  device  will  beep  three  times  to  confirm.  The 

red  LED  will  go  out  and  the  device  will  switch  to 

normal operation. 

ACCESSING PROGRAMMING 

MODE

Programming  mode  may  be  used  to  configure 

operation of the device and to save or edit access 

codes.

Press 

 

X

 

.

Enter the password and press 

.

The device will beep three times and the red LED 

will  light  up  for  confirmation:    the  device  is  in 

programming mode.

Either hold 

X

 pressed for at least three second or 

leave the device inactive for more than 30 seconds 

to quit programming mode.

RELAY OPTIONS 

PROGRAMMING PROCEDURE

Access programming mode.

Enter the configuration code 

nn a b ss

 where:

nn

  is  the  relay  to  be  configured;  possible  values 

are:

 

31 = relay 1

 

3 = relay 

a

   defines whether the code needs to be confirmed 

by  pressing  the  button 

 

or  not;  possible 

values are:

 

1 =  relay activation entering the code only

 

 =  relay  activation  entering  the  code  and 

pressing the button 

 

to confirm.

b

   defines  the  relay  activation  mode;  possible 

values are:

 

1 = monostable activation

 

 = toggle activation 

ss

   defines  the  activation  time  expressed  in 

seconds; possible values are:

 

00  =  00ms  (set  this  value  for  toggle 

operation)

 

01 = 1 second

 

..

 

99 = 99 seconds

Press 

 

to confirm.

The device will beep three times and the red LED 

will blink three times.

If the entered code is wrong, the device will beep 

twice in rapid succession and wait for the correct 

code to be entered.

ACTIVATION CODE STORAGE 

PROCEDURE

Access programming mode.

Enter configuration code 

nn xxxxxxxx

 where:

nn

  

defines  the  code  memory  location; 

possible values from 01 to .

xxxxxxxx

 activation code (from 3 to  8 digits).

Press 

 

to confirm.

Define the number of relays to be activated with the 

code shown:

1 = relay 1

 = relay 

Press 

 

to confirm.

The device will beep three times and the red LED 

will blink three times.

If the entered code is wrong, the device will beep 

twice in rapid succession and wait for the correct 

code to be entered.

Отзывы: