background image

8

DS1060-119A

3  CONNECTION INSTRUCTIONS

Refer to the instructions contained in the system manual for wiring, maximum distances and con

fi

 guration 

operations.

3.1  CONNECTOR AND WIRING WITH CAT5 WIRE

Use Urmet RJ45 connector kit for connections (product on sale until stocks last).

Connect the CAT5 wire to one of the RJ45 connectors with Urmet logo:

Insert the wire in the guide respecting the colour coding shown (Standard T568B).

8

1

Wire

No.

Wire colour

1

White-Orange

2

Orange

3

White-Green

4

Blue

Wire

No.

Wire colour

5

White-Blue

6

Green

7

White-Brown

8

Brown

Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and 

crimp the plug with a speci

fi

 c tool.

Plug

8

1

~ 5 mm

8

1

  Make sure that the grey sheath remains inside the plug.

  This type of connection DOES NOT ensure double insulation..

4  TECHNICAL SPECIFICATIONS 

Power voltage and consumption on terminals V+ e V-

Power voltage: ...............................................................................................................................

44 – 57 Vdc

Max. consumption (video call) @48 V: .................................................................................................

200 mA

Max. consumption (stand-by) @48 V: ....................................................................................................

80 mA

Working temperature range: ..................................................................................................

-10 °C ÷ +50 °C

Relay contact range C, NC, NO:

Maximum switching voltage:  ....................................................................................................................

30 V

Maximum switching current:  ...................................................................................................................

3,5 A

Maximum switching load: .............................................................................................................

40 VA 25 W

Garage gate relay contact range (SE2):

Maximum switching voltage:  ....................................................................................................................

30 V

Maximum switching current:  ...............................................................................................................

200 mA

Max. distance from hall button:  .............................................

25 m with cable cross-section area 0.5 mm

2

Max. distance from open door sensor:  .................................

50 m with cable cross-section area 1.5 mm

2

Max. distance from supplementary power supply:  .............

100 m with cable cross-section area 1.5 mm

2

Max. distance from capacitance lock:  ................................

100 m with cable cross-section area 1.5 mm

2

  Clean regularly with products suitable for metallic surfaces to keep the push-button panel looking 

good in time. Do not use aggressive chemical products (e.g. solvents, ammonia, soda, etc.).

Содержание IPercom elekta steel 1060/18

Страница 1: ...DS 1060 119A LBT 20376 Mod 1060 MODULO DI CHIAMATA ELEKTA STEEL ELEKTA STEEL CALL MODULE MODULE D APPEL ELEKTA STEEL MÓDULO DE LLAMADA ELEKTA STEEL RUFMODUL ELEKTA STEEL Sch Ref 1060 18 ...

Страница 2: ...or local power supply 125 kHz integrated transponder key reader Ref 1125 50 Infrared proximity sensor for user detection CCD colour camera with wide angle lens Alphanumeric keypad with 18 buttons three of which multifunctional 2 INSTALLATION Arrange the duct so that it ends in correspondence with the lower hole of the flush mounting box Remove the lower cap from the wire hole 1 Apply adhesive labe...

Страница 3: ...lock relay contact NO Normally open lock relay contact SE Discharge lock terminals SE V Auxiliary power terminals V PA Hall button terminals for operating lock relay SP Open door sensor terminals SE2 Garage gate contact terminals NO AD Auxiliary power terminals LAN Ethernet connector for LAN RJ45 READER Connector for integrated transponder key device ALTO TO P HAU T Screw M4 x 20 Antitheft special...

Страница 4: ...nection DOES NOT ensure double insulation 4 TECHNICAL SPECIFICATIONS Power voltage and consumption on terminals V e V Power voltage 44 57 Vdc Max consumption video call 48 V 200 mA Max consumption stand by 48 V 80 mA Working temperature range 10 C 50 C Relay contact range C NC NO Maximum switching voltage 30 V Maximum switching current 3 5 A Maximum switching load 40 VA 25 W Garage gate relay cont...

Страница 5: ...em system installation paragraph 6 SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby URMET S p A declares that the radio equipment type ELEKTA STEEL CALL MODULE Ref 1060 18 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address www urmet com ...

Страница 6: ...BT 20376 Area tecnica servizio clienti 39 011 23 39 810 http www urmet com e mail info urmet com MADE IN ITALY URMET S p A 10154 TORINO ITALY VIA BOLOGNA 188 C Telef 39 011 24 00 000 RIC AUT Fax 39 011 24 00 300 323 ...

Отзывы: