Interfacing IPerCom lock output to iPassan access control system -
Fv
51
00
+
-
FD
-0
20
-1
66
C NC NO
PA SP SE2 AD
SE+ SE- V V
+ -
1104/921 iPassan controller or
1104/926 iPassan 2-Reader expansion card
iPassan panel mount reader
Use this method to interface to any access control
system; use the C and NO connections of the
IPerCom
entry panel to trigger the exit switch input of the access
control system. Use the access control system to
control the release or maglock
-
+
R
+/
D
+
R
-/
D
-
R
EX
+
R
EX
-/
D
C
-
D
C
+
C
N
C
N
O
The
IPerCom
volt free relay lock output is connected to
the exit switch input of the
iPassan
controller. The
IPerCom
relay time should be programmed to 1 second
and the actual door open time required is programmed
via the
iPassan
(or third party) access control system.