8
DS1375-024A
3 CONNECTION INSTRUCTIONS
•
Connect the CAT5 wire to one of the RJ45 connectors with Urmet logo:
•
Insert the wire in the guide respecting the colour coding shown (Standard T568B).
8
1
Wire
No.
Wire colour
1
White-Orange
2
Orange
3
White-Green
4
Blue
Wire
No.
Wire colour
5
White-Blue
6
Green
7
White-Brown
8
Brown
•
Cut the wires which protrude from the guide by approximately 5mm, insert the guide in the plug and
crimp the plug with a
tool.
Plug
8
1
~ 5 mm
8
1
•
Make sure that the grey sheath remains inside the plug.
This type of connection DOES NOT ensure double insulation.
Wires with cross-section area of 0.5 mm
2
or larger must comply with IEC 60332-1-2; wires with
cross section area smaller than 0.5 mm
2
must comply with IEC 60332-2-2.
4 TECHNICAL SPECIFICATIONS
Power voltage and consumption on terminals V+ e V-
Power voltage:...............................................................................................................................
44 – 57 Vdc
Max. consumption (video call) @48 V: .................................................................................................
200 mA
Max. consumption (stand-by) @48 V: ....................................................................................................
80 mA
Working temperature range: ..................................................................................................
-10 °C ÷ +50 °C
Relay contact range C, NC, NO:
Maximum switching voltage: ....................................................................................................................
30 V
Maximum switching current: ...................................................................................................................
3,5 A
Maximum switching load: .............................................................................................................
40 VA 25 W
Garage gate relay contact range (SE2):
Maximum switching voltage: ....................................................................................................................
30 V
Maximum switching current: ...............................................................................................................
200 mA
Max. distance from hall button: .............................................
25 m with cable cross-section area 0.5 mm
2
Max. distance from supplementary power supply: .............
100 m with cable cross-section area 1.5 mm
2
Max. distance from capacitance lock: ................................
100 m with cable cross-section area 1.5 mm
2
Содержание ELEKTA STEEL 1375