31
DS1083-135
VIDEO DOOR PHONE SYSTEMS
VIDEO DOOR PHONE RISERS CONNECTION
This chapter shows the different ways of connecting a riser with at least one video door phone regardless of
whether it is derived from a column power supply unit, a column distributor or a column interface.
Special decoders and door phone connections are similar, but special decoders must be installed
at the end of a branch. On the decoder In/out connection can not be performed.
Connection of a video door phone riser with distributors
A
Bv
1
2
N
A = distance between the 4-user distributor and the apartment station
Bv = distance between the device from which the riser is derived and the most distant 4-user distributor
Cable
Number of apartment
stations according to the
device from which the
riser is derived
video
distance
1083/23
1083/53 or /50
A
Bv
A+Bv
2Voice cable Ref. 1083/92
48
32
Colour
50m
200m 200m
B/W
50m
200m 200m
2Voice cable Ref. 1083/94
48
32
Colour
50m
125m 125m
Ø 0,6mm telephone pair without sheath
48
32
Colour
50m
150m 150m
B/W
50m
125m 125m
CAT5 UTP (one twisted pair)
48
32
Colour
50m
125m 125m
B/W
50m
75m
75m
HVV05-F 1,5 mm
2
rubber covered
48
32
Colour
50m
125m 125m
B/W
50m
125m 125m
7057/235 Urmet cable (blue/red)
48
32
Colour
50m
125m 125m
B/W
50m
125m 125m
1mm
2
section single cable
32
32
Colour
50m
50m
75m
B/W
50m
50m
75m
For system extensions and connection of street side branch and call stations see the next
paragraphs.