18
DS1784-001
3.3.3 SW2
settings
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
1 second
3 seconds
6 seconds
9 seconds
Door opener time: the positions of dip-switches 1 and 2 (DOOR TIME) determine the activation time of the
pedestrian gate lock.
Dip 3
Auto-on restriction
Dip 4
Address management
Dip 5
Door status
or Letterbox function
Dip 6
Camera
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
2
1
4
3
ON
6
5
Service
not active
Service
active
Service
active
Service
not active
Door Status
50 Hz
Letter Box
60 Hz
Auto-on restriction with even ID code: DIP switch 3 allows the user group with even ID code to use the
video auto-on function only on door units with even address ID=0 (if secondary) or ID=2; consequently,
users with odd ID code may used the auto-on function in video mode only on door units with odd address
ID=1 (both main and secondary) or ID=3.
During door unit auto-on, the audio line will be also available (if the user started a conversation) in addition
to the door opener service.
The service works with main and secondary video door units, except for the case of MAIN door unit with
ID=0 that all users must be able to use in auto-on mode.
Call button address management: the position of the DIP switch 4 can be used to change the call address
of the door unit button. The function must only be changed on the single-family panel Ref. 1784/1.
SW2 DIP switch 4
Call
OFF
Apartment station with code 0
ON
Apartment station with code 1
Door status or Letterbox: DIP switch 5 can be used to manage input SP for the DOOR STATUS or
LETTERBOX functions (future implementation).
50/60 Hz camera: DIP switch 6 can be used to set the frequency of the camera.
3.3.4 SW1 rotary switch
The position of the rotary switch determines a guaranteed conversation time, i.e. extends the busy time
from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
Pos. 0
1 second
Pos. 5
50 seconds
Pos. 1
10 seconds
Pos. 6
60 seconds
Pos. 2
20 seconds
Pos. 7
70 seconds
Pos. 3
30 seconds
Pos. 8
70 seconds
Pos. 4
40 seconds
Pos. 9
70 seconds
The guaranteed conversation time must be programmed in the same way for all system call
stations.