14
DS1783-002C
DOOR OPENING TIME
The position of these dipswitches (DOOR TIME) determines the activation time of
the main entrance electric lock
ON
2
Instantaneous
1
3 s
6 s
ON
2
9 s
1
ON
2
1
ON
2
1
GUARANTEED CONVERSATION TIME
The position of the rotary switch (CONV TIME) determines a
guaranteed conversation time, i.e. extends the busy time from the answer onwards.
The busy time is equal to the reply time (max. 60s) added to the guaranteed conversation time.
Pos. 0 = 1 s
Pos. 1 = 10 s
Pos. 2 = 20 s
Pos. 3 = 30 s
Pos. 4 = 40 s
Pos. 5 = 50 s
Pos. 6 = 60 s
Pos. 7 e 8 = 70 s
Pos. 9 = high level programming
The guaranteed conversation time must be programmed in the same way for all system call
stations.
TYPES OF SYSTEMS
Single-family system
2Voice
power supply
LINE 2
LINE 1
Calling station
ID = 0
AUX dip 1 = OFF (main)
AUX dip 6 = OFF (single-family)
Apartment station
CODE = 0
INT = 0
Two-family system
2Voice
power supply
LINE 2
LINE 1
Calling station
ID = 0
AUX dip 1 = OFF (main)
AUX dip 6 = ON (two-family)
Apartment station
User 1
CODE = 1
INT = 0
Apartment station
User 0
CODE = 0
INT = 0