![urmet domus 1072/59 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/urmet-domus/1072-59/1072-59_technical-manual_1062467003.webp)
ACCESSORIES
sec.4c
−−−−
3
2GO! - Technical manual
PROGRAMMING
ON
=
OFF
=
ON
ON
SWITCHING MODE
Firstly, de
fi
ne whether the relay must be controlled in monostable or
toggle mode.
In monostable mode, when an appropriate command is received or
the remote button connected to the PC terminals is pressed, the relay
will be energised for a variable time from 1 second to 10 minutes
according to the setting made using the “timer” trimmer.
In toggle mode, when an appropriate command is received or the
remote button connected to the PC terminals is pressed, the relay will
switch and the trimmer setting will be ignored. The relay will remain
switched until a new command is reached.
ON
DIP
4
3
2
1
5
ON
3
2
1
ON
2
1
ON
2
1
ON
DIP
4
3
2
1
5
Toggle
Monostable
ON
PE
NA
INF
SUP COD M/T
PROG
TIMER
OFF=M
ON=T
ON
ON
Sch.1082/80
NC
C
Z
PC
LINE
To test the operation time in monostable mode, simply short circuit
the PC terminals provisionally and check the relay energising time.
OPERATING MODE
The special decoder can be con
fi
gured to be activated by a call (from
a door or intercom unit) by a user code (from 0 to 31) if this is not
already used by apartment stations. Alternatively, it can be activated
by other system events (pressing a door opening button on an
apartment station, pressing the call to switchboard button, pressing
the staircase light button on an apartment station or door unit).
A - OPERATION FOLLOWING A CALL
The position of the PE dip switch is ignored:
ON
DIP
4
3
2
1
5
ON
3
2
1
ON
2
1
ON
DIP
4
3
2
1
5
ON
PE
NA
INF
SUP COD M/T
PROG
TIMER
OFF=M
ON=T
ON
ON
Sch.1082/80
NC
C
Z
PC
LINE
ON
3
2
1
Arrange the COD dip switch in the on position:
ON
DIP
4
3
2
1
5
ON
3
2
1
ON
2
1
ON
DIP
4
3
2
1
5
ON
PE
NA
INF
SUP COD M/T
PROG
TIMER
OFF=M
ON=T
ON
ON
Sch.1082/80
NC
C
Z
PC
LINE
ON
1
2
At this point, assign a user code from 0 to 31 to the special decoder.
To do this, set the INF and SUP dip switches to the same value as
the user code chosen using the following table. This code must
not
correspond
to another user code in the system.
INF/SUP= 6
4
3
2
1
5
INF/SUP= 5
4
3
2
1
5
INF/SUP= 4
4
3
2
1
5
INF/SUP= 7
4
3
2
1
5
INF/SUP= 10
4
3
2
1
5
INF/SUP= 9
4
3
2
1
5
INF/SUP= 8
4
3
2
1
5
INF/SUP= 11
4
3
2
1
5
INF/SUP= 14
4
3
2
1
5
INF/SUP= 13
4
3
2
1
5
INF/SUP= 12
4
3
2
1
5
INF/SUP= 15
4
3
2
1
5
INF/SUP= 18
4
3
2
1
5
INF/SUP= 17
4
3
2
1
5
INF/SUP= 16
4
3
2
1
5
INF/SUP= 19
4
3
2
1
5
INF/SUP= 22
4
3
2
1
5
INF/SUP= 21
4
3
2
1
5
INF/SUP= 20
4
3
2
1
5
INF/SUP= 23
4
3
2
1
5
INF/SUP= 26
4
3
2
1
5
INF/SUP= 25
4
3
2
1
5
INF/SUP= 24
4
3
2
1
5
INF/SUP= 27
4
3
2
1
5
INF/SUP= 2
4
3
2
1
5
INF/SUP= 1
4
3
2
1
5
INF/SUP= 0
4
3
2
1
5
INF/SUP= 3
4
3
2
1
5
INF/SUP= 30
4
3
2
1
5
INF/SUP= 29
4
3
2
1
5
INF/SUP= 28
4
3
2
1
5
INF/SUP= 31
4
3
2
1
5
At this point, the special decoder is ready to be activated by door
units by means of the programmed call code.
To be activated from an apartment station, the special decoder call
codes must be programmed for all apartment stations which need to
access the service as follows:
1. Go to the apartment station to be programmed.
2. Hold the door opener button pressed and pick up the handset. The
apartment station outputs a tone to indicate that programming is
in progress.
BEEP
1
2
SPECIAL DECODING Ref. 1082/80
PROGRAMMING
SPECIAL DECODING
Ref. 1082/80
Содержание 1072/59