DIGITALIZER REF. 1052/7R
USER MANUAL / CONFIGURATION AND ADJUSTMENT
6
USER MANUAL
CALLING TO DOORPHONES
To call doorphone press (without holding) selected button. To
disconnect press again the button.
DOOR OPENING WITH DALLAS KEY
If call module is equipped with Dallas key reader, it is possible to
open the door with Dallas key. To do it ,close the Dallas key to the
reader. If system recognize the key, call module will generate
confirmation signal, electric lock will be released and doorphone
assigned to this key will generate beep as well.
USE OF R OUTPUT
Digitalizer is equipped with
R
button (
OC
open collector output).
Output is active (connected with GND) from call time to the end of
conversation time of any user. This output is dedicated to video
systems.
USE OF EXI OUTPUT
Digitalizer is equipped with controlled
EXI
terminal. By default
EXI
terminal is connected with
GND
. If we replace jumper with any
sensor (eg: contactor), call module will respond to any interruption
of the circuit between
EXI
and
GND
terminals. It will result with
connecting relevant
EO
output to +20V output in power supply. This
function can be used for example to unclosed door signalization.
USE OF PH INPUT
Digitalizer is equipped with
PH
terminal, which can be used as a
local opening door button. Shorting
PH
and
GND
terminals will
result in electric lock releasing for programmed time. In another
words, to realize opening door function just press the button which
will short
PH
and
GND
terminals.
CONFIGURATION AND ADJUSTMENT
Jumper
Description
Dip-switch
(jumper)
position
Function
ADDRESS
Address
setting
Dip-switch settings
table
COMMUNIC
ATION
MODULE
Communica
tion module
selection.
MATIBUS
SE
communication
module
COMMUNIC
ATION
MODULE
Communica
tion module
selection.
RS485
communication
module
ELECTRIC
LOCK
CURRENT
Setting
current of
electric.
150 mA (reversed
electric lock)
ELECTRIC
LOCK
CURRENT
Setting
current of
electric.
300 mA
ELECTRIC
LOCK
CURRENT
Setting of
current of
electric.
600 mA
PROG
Save
Programming button
Standard communication module is used in systems based on
power supplies
ref. 1052/33
and
ref. 1052/31A
.
RS485
communication module is used in systems based on power supplies
ref. 1052/33R
and
ref. 1052/31R.
If a change (eg: electric lock time release) in digitalizer is needed it
is required to use call module
ref. 1052/100..100D
.
By default this device is pre-adjusted during production. Do not
change potentiometer settings until it is necessary.
Mark
Description
P1
Call module microphone gain adjustment
P2
Call module speaker gain adjustment