DIGITALIZER REF. 1052/7R
PROGRAMMING
5
DALLAS KEY PROGRAMMING
To program the Dallas key:
•
Set doorphone’s power supply ID with ADDRESS dip-switch
(only when digitalizer is attached to main channel). If digitalizer
is attached to an additional channel skip this step – set any ID.
Dip-switch 1 is the least significant and 8 is the most significant
part of address.
•
Press shortly PROG button. Call module attached to this
digitalizer will generate confirmation sound and LED on
digitalizer will turn on as well.
•
Set physical address of given doorphone with dip-switches
(ADDRESS dip-switch). Dip-switch 1 is the least significant
and 8 is the most significant part of address. Dip-switch 9
specify riser number (ON – riser 2, OFF – riser 1). During
setting the LED should be turned on.
•
Press shortly PROG button. LED should start to blink.
•
Close the Dallas key to the reader. After successful
programming double beep will be generated and LED will stop
blinking. After failure (Dallas key is already assigned) error
signal will be generated and LED will blink three times and turn
off.
•
In order to program another Dallas key (doorphone is
connected to the same power supply) set address of next
doorphone (with dip-switches) and repeat the rest of the
programming procedure.
•
Press and hold for about 4 seconds PROG button to exit
programming mode.
PROGRAMMING OF CALL BUTTON IN SWITCHBOARD
STATION
To program a call button in switchboard station:
•
If digitalizer is attached to the main channel, set address (with
dip-switches) of MASTER power supply. If digitalizer is
attached to an additional channel skip this step – set any
address. Dip-switch 1 is the least significant and 8 is the most
significant part of address.
•
Press shortly PROG button. Call module attached to this
digitalizer will generate confirmation sound and LED on
digitalizer will turn on as well.
•
Set 1 -8 dip-switches to OFF and dip-switch 9 to ON. During
setting the LED should be turned on.
•
Press shortly PROG button. LED in digitalizer should start to
blink.
•
Press selected button in call module to program it. After
successful programming double beep will be generated and
LED will stop blinking. After failure single beep will be
generated and LED will still be blinking.
•
Press and hold for about 4 seconds PROG button to exit
programming mode.