background image

APARTMENT DOOR PHONE STATIONS

sec.5a 

−−−− 

23

DIGIVOICE - Technical Manual

DOORPHONE WITH SINGLE-PORT DECODER

Ref. 38/3

FEATURES

The doorphone provides the following features:

• 

Electronic  call  tone  signaling  via  a  dedicated  outward-facing 

speaker.

• 

Ringer  volume  adjustment  through  jumper  connection  or  ringer 

volume control kit Ref. 1132/53.

• 

Voice calls.

• 

Door lock release function.

• 

Conversations and door lock release function protected by privacy 

feature.

• 

Calls to guard door switchboard station.

• 

Calls to special doorphone.

• 

Call from landing function.

• 

Video module management.

• 

Manages self-activation function.

• 

Provision for programming (and checking programmed codes) with 

system off, using programming terminal Ref. 1038/56.

• 

Courtesy tones.

• 

Provision for connection with an additional doorphone.

The doorphone with single-port decoder consists of the following:

1)   Programming/data line LED.

2)   Volume jumper connection.

3)   Terminal  block  for  connection  to  power  supply,  data  and  voice 

riser cable - (M1).

4)   Terminal block for connection to call from landing pushbutton and 

video signal enabling - (M2).

5)   Terminal block for connection to additional doorphone - (M3).

6)   Base.

7)   Programming data label.

8)   Handset.

90 mm

69 mm

220 mm

COL: ______

A: ________

T1: _______

T2: _______

13

12

7

8

9

10

11

1

2

6

5

4

3

DOORPHONE WITH SINGLE-PORT DECODER Ref. 38/3

FEATURES - SPECIFICATIONS - OPERATION

9)   Ringer/courtesy tone speaker.

10)  Top casing.

11)  Programming connector.

12)  Printed circuit.

13)  Programming key.

TERMINAL DESIGNATIONS

RISER COLUMN TERMINAL BLOCK - (M)

FB   Voice terminal B (return voice conductor)

FA   Voice terminal A (outward voice conductor)

D  

Data bus terminal

0V   Power supply ground terminal

+V   +24 V DC power supply terminal

CALL  FROM  LANDING/vIDEO  SIGNAL  ENABLING  TERMINAL 

BLOCK - (M2)

CV   Video signal enabling terminal

CP   Call from landing terminal

0V   Ground terminal (reference for CP and CV)

 

TERMINAL  BLOCK  FOR  ADDITIONAL  DOOR  PHONE 

CONNECTION - (M3)

FB   Voice terminal B

FA   Voice terminal A

CA   Ringer and service terminal

0V   Ground terminal (reference for CA)

SPECIFICATIONS

Consumption in load units (LU):  

.5LU

Supply voltage:  

2 to 25.2vdc

Max. current draw:  

50mA

Service temperature range:  

-5°C to 45°C

OPERATION

Doorphone  with  single-port  decoder  can  be  used  for  voice  calls 

with  entrance  modules,  guard  door  switchboard  stations  or  special 

doorphones.

The doorphone is provided with a door lock release key. When the key 

is pressed, the unit emits a courtesy tone to indicate that the lock has

been released.

During  programming  (see  the  paragraph  headed  ‘Programming’), 

a  riser  column  code,  a  user  code  and  codes  associated  with  two 

additional  keys  (optional)  must  be  assigned.  All  of  these  codes  are 

resident  on  an  EEPROM  memory  which  guarantees  that  they  are 

retained even with power off.

During operation, the doorphone with single-port decoder analyzes the 

code emitted by the calling device and, if it corresponds to the code for 

which it has been programmed, the doorphone will accept the call.

The conversation can last up to ten minutes if no calls are made to 

another user. The video signal (where applicable) will remain for the 

entire duration of the conversation.

After the 10-minute time-out period, or if the call is interrupted by a 

call to another user, the doorphone with single-port decoder sends a 

courtesy tone to the connected station to inform the user that the call 

has been interrupted.

The doorphone with single-port decoder is provided with three special 

keys which can be used to send command signals:

• 

Door Lock Release.

• 

Call Switchboard.

• 

Call Special Doorphone.

The doorphone emits a courtesy tone each time one of these signals is 

sent. Only one door lock release signal is needed, even if the system 

includes several outdoor stations, each with an electric lock: actuating

the door lock release key will open the electric lock only at the outdoor 

station from which the call was made.

DOORPHONE WITH SINGLE-PORT DECODER

Ref. 

38/3

Содержание 1038/40

Страница 1: ...eedback monitoring 11 SPECIAL FUNCTIONS 11 Date time adjustment 11 Keypad lock activation deactivation 11 Call rerouting 12 Other display messages 12 Using a printer 12 Management from PC using pcvoic...

Страница 2: ...apted for tabletop or wall mounting see the section covering installation COMPONENTS 1 Switchboard station body 2 Graphic display 3 Multi function keypad 4 Ringer volume control 5 Handset 6 Handset cr...

Страница 3: ...ode of the apartment station called by the switchboard station Zone f 1 character This zone shows a symbol indicating the type of voice connection This symbol may be when main entrance panel eee has c...

Страница 4: ...rd station can call any apartment station The switchboard station will normally receive calls from the apartment stations only if they belong to its assigned zone If desired the switchboard attendant...

Страница 5: ...e mode A B or C Mode A Call interception enabled In this mode the switchboard station provides concierge service intercepting calls from main entrance panels to apartment stations Calls belong to the...

Страница 6: ...Case 2 System with several switchboard stations in parallel Where there are two or more switchboard stations operating in parallel i e when the same zone is assigned to all switchboard stations the s...

Страница 7: ...o apartment stations To call an apartment station the switchboard attendant must pick up the handset dial the apartment station code using the numeric keys 37 and press the call button If incorrect co...

Страница 8: ...rom apartment station 1634 If the handset is picked up within 10 seconds the device will be ready for communication between the switchboard station and the apartment station and the display will show...

Страница 9: ...on hold and switch the voice line to the main entrance panel by pressing key put the main entrance panel on hold and switch the voice line to the apartment station by pressing key or reestablish direc...

Страница 10: ...panel 2 by pressing key 1 2 The display will show DOOR LOCK RELEASE FUNCTIONS The switchboard station can release locks at any door associated with a main or secondary entrance panel at any time This...

Страница 11: ...MESSAGES SELF ACTIVATION FUNCTION The switchboard station can activate the main entrance modules by means of the self activation function In other words the switchboard attendant can establish video a...

Страница 12: ...with a date time stamp Configuration report This report is printed at the end of switchboard station configuration and indicates all settings established for the station Door lock release messages Pri...

Страница 13: ...ist 39 and click on button 41 an OK button and a Cancel button will appear Click on the OK button to confirm removal or on the Cancel button to exit from the procedure without making changes Editing a...

Страница 14: ...supplied together with the unit inserting them through holes 8 PC VERSION INSTALLATION The switchboard station can be controlled from a PC In this case the PC s keyboard and mouse are used instead of...

Страница 15: ...ay STEP 0 LANGUAGE The following menu will appear on the switchboard station display The following languages can also be programmed Press the number key associated with the desired language STEP 1 SWI...

Страница 16: ...istobeconfiguredtohandletwo simultaneous calls select 2 For this purpose however the switchboard station and the main entrance panels must be physically connected by two separate voice lines STEP 5 CO...

Страница 17: ...hange the function associated with key F1 simply select the desired number using the appropriate number key as indicated below and press the call button Select 0 to specify that no function is assigne...

Страница 18: ...DE TO THE FUNCTIONS KEY Proceed as for step 12A STEP 18 PROGRAMMING THE ACCESS PASSWORD The display will show To change the password simply enter up to six numbers as desired and press the call button...

Страница 19: ...rtment stations Ability to receive calls from other apartment stations can be disabled Disabled status is indicated by a LED Up to 10 unanswered calls from apartment stations can be stored in memory A...

Страница 20: ...s in sequence Activate the configuration cycle noting the following points After selecting each parameter press the CALL button 4 to confirm selection The system will check all entered data rejecting...

Страница 21: ...it is necessary to open the door RECEIVING AND STORING CALLS FROM OTHER APARTMENT STATIONS The special doorphone can receive calls from other apartment stations in the system and store unanswered call...

Страница 22: ...d deactivate the feature simply press the SHIFT and MUTE keys 5 10 When the feature is active LED 11 flashes green Obviously the feature can be activated together with the MUTE function or separately...

Страница 23: ...nd CV TERMINAL BLOCK FOR ADDITIONAL DOOR PHONE CONNECTION M3 FB Voice terminal B FA Voice terminal A CA Ringer and service terminal 0V Ground terminal reference for CA SPECIFICATIONS Consumption in lo...

Страница 24: ...y a second courtesy tone will be emitted after 10 seconds CALLS FROM LANDING VIDEO MODULE Doorphone with single port decoder is designed to control video module Ref 1732 1 with associated wall bracket...

Страница 25: ...e The programming cycle ends when the last code is received and the LED will go off Programming conditions and the corresponding LED states are shown in the table below If it is not necessary to progr...

Страница 26: ...lease key Conversation privacy and provision for door lock release protected by privacy feature No door phone programming required during installation Two buttons for switchboard calls and auxiliary s...

Страница 27: ...aker for ringing tone Electret condenser microphone Door lock release key Conversation privacy and provision for door lock release protected by privacy feature No door phone programming required durin...

Страница 28: ...nel activation upon making a call to switchboard with optional additional circuit Ref 1138 55 Dimensions W x H x P 90 x 220 x 42mm TERMINAL DESIGNATIONS 0V Logic power supply negative input CA Ringer...

Страница 29: ...g cables through hole 11 5 Reassemble switchboard station and supply it with power Note the telephone interface or PABX connecting cables must be less than 3 meters long TERMINAL DESIGNATIONS The conn...

Страница 30: ...30 sec 5a DIGIVOICE Technical Manual...

Отзывы: